How to use this calculator
Estimate volatile-solids reduction from feed and digested-sludge tests.
- Enter Feed volatile solids (% of total solids), Digested-sludge volatile solids (% of total solids). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The EPA in-out test estimates digester efficiency from the volatile-solids percentage of total solids in feed and digested sludge. The method uses the ash fraction as a conserved reference when comparing incoming and outgoing sludge.
Inputs and units
vsInPercent— Feed volatile solids (% of total solids)- Volatile-solids fraction in digester feed.
vsOutPercent— Digested-sludge volatile solids (% of total solids)- Volatile-solids fraction in digested sludge.
Formula
P (%) = (In − Out) ÷ (In − In × Out) × 100, where In and Out are volatile-solids fractions of total solids.
Method
Enter volatile solids as a percentage of total solids for feed and digested sludge. Use representative paired samples from the same operating period.
Worked example
Feed at 70% volatile solids and digested sludge at 50% gives (0.70−0.50)/(0.70−0.70×0.50) × 100 = 57.14% estimated reduction.
Assumptions and limits
This is the EPA in-out estimate, not a direct solids mass balance. A negative result indicates the measured outgoing volatile-solids fraction exceeded the incoming fraction; review sampling and process conditions.
Frequently asked questions
Why are both values percentages of total solids?
The EPA in-out test compares volatile-solids shares in feed and digested-sludge total solids.
What does the result mean?
A rising trend in reduction can indicate improved stabilization, but interpret it with representative samples and operating context.
What should I compare it with?
Compare runs using the same volatile-solids test and feed/sludge sampling basis; both values are shares of total solids, not wet-feed percentages.
How do I use the Anaerobic Digester Volatile Solids Reduction Calculator?
Enter Feed volatile solids (% of total solids), Digested-sludge volatile solids (% of total solids). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Anaerobic Digester Volatile Solids Reduction?
Feed at 70% volatile solids and digested sludge at 50% gives (0.70−0.50)/(0.70−0.70×0.50) × 100 = 57.14% estimated reduction.
Reference: U.S. EPA pollutant loading and wastewater flow methodology. See our calculation methodology.