Wastewater BOD Removal Efficiency Calculator

Estimate wastewater treatment biochemical oxygen demand removal from matched influent and effluent BOD₅ concentrations.

4,000 tools
Wastewater BOD Removal Efficiency Calculator — Influent BOD₅ concentration (mg/L), Effluent BOD₅ concentration (mg/L) and calculation method
Wastewater BOD Removal Efficiency Calculator: inputs and calculation method.

How to use this calculator

Estimate wastewater treatment biochemical oxygen demand removal from matched influent and effluent BOD₅ concentrations.

  1. Enter Influent BOD₅ concentration (mg/L), Effluent BOD₅ concentration (mg/L). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Water engineering calculation

How this calculation works

BOD removal efficiency compares the decrease in biochemical oxygen demand concentration across a treatment step with its influent concentration. This calculator uses two concentrations on the same analytical basis and reports percent removal and the concentration decrease.

Inputs and units

influentBod — Influent BOD₅ concentration (mg/L)
Biochemical oxygen demand entering the treatment step on the stated analytical basis.
effluentBod — Effluent BOD₅ concentration (mg/L)
Biochemical oxygen demand leaving the same treatment boundary and period.

Formula

Displayed formula

BOD removal (%) = (influent BOD₅ − effluent BOD₅) ÷ influent BOD₅ × 100.

Method

Use influent and effluent BOD₅ values from the same treatment boundary and comparable sampling period. The calculation reports concentration removal, not a flow-weighted mass-load balance.

Worked example

An influent BOD₅ of 300 mg/L and effluent BOD₅ of 60 mg/L give 80.00% concentration removal and a 240 mg/L decrease.

Assumptions and limits

Concentrations must use the same units and analytical basis, and effluent must not exceed influent for this removal metric. Concentration differences can misstate load removal when flow changes; use flow-weighted loads when needed.

Frequently asked questions

Does this calculate BOD mass-load removal?

No. It compares concentrations; use flow-weighted loads if flow changes across the treatment boundary.

Do samples need matching units?

Yes. Use the same BOD test, units, and representative sampling scope for both values.

Does high removal guarantee a compliant effluent?

No. Compliance depends on the applicable permit and effluent concentration limits, not removal percentage alone.

How do I use the Wastewater BOD Removal Efficiency Calculator?

Enter Influent BOD₅ concentration (mg/L), Effluent BOD₅ concentration (mg/L). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Wastewater BOD Removal Efficiency?

An influent BOD₅ of 300 mg/L and effluent BOD₅ of 60 mg/L give 80.00% concentration removal and a 240 mg/L decrease.