CalcWorldHub
Free online calculator · no signup

Anisotropic conductivity tensor heat flux direction calculator

Calculate heat-flow components and oriented-surface flux in a material whose conductivity differs by direction.

4,000 tools
Anisotropic conductivity tensor heat flux direction calculator — Conductivity tensor Kxx (W/m/K), Conductivity tensor Kyy (W/m/K), Conductivity tensor Kzz (W/m/K) and calculation method
Anisotropic conductivity tensor heat flux direction calculator: inputs and calculation method.

How to use this calculator

Calculate heat-flow components and oriented-surface flux in a material whose conductivity differs by direction.

  1. Enter Conductivity tensor Kxx (W/m/K), Conductivity tensor Kyy (W/m/K), Conductivity tensor Kzz (W/m/K), Symmetric coupling Kxy (W/m/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Anisotropic conductivity tensor heat flux direction explained

Heat flux component x-1020W/m²
Heat flux component x: -1020 W/m² in the worked scenario.

A numerical walkthrough

Conductivity tensor Kxx (W/m/K) = 10; Conductivity tensor Kyy (W/m/K) = 2; Conductivity tensor Kzz (W/m/K) = 1; Symmetric coupling Kxy (W/m/K) = 1; Symmetric coupling Kxz (W/m/K) = 0; Symmetric coupling Kyz (W/m/K) = 0; Temperature gradient x y z (K/m) = [100, 20, 0]; Surface normal x y z = [1, 0, 0].

  • Heat flux component x: -1020 W/m²
  • Heat flux component y: -140 W/m²
  • Heat flux component z: 0 W/m²
  • Heat flux through oriented surface: -1020 W/m²

For Kxx=10, Kyy=2, Kzz=1 and Kxy=1 W/m/K, a gradient [100,20,0] K/m gives flux [−1,020,−140,0] W/m². The nonparallel vectors show why a scalar conductivity cannot capture the entered cross-coupling.

The model behind the numbers

q=−K∇T; qn=q·n/||n||; K is symmetric positive definite.

Apply the tensor form of Fourier law in one orthonormal coordinate system. Positive definiteness ensures that heat conduction produces nonnegative entropy generation.

What to enter

kx — Conductivity tensor Kxx (W/m/K)
Conductivity tensor Kxx (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
ky — Conductivity tensor Kyy (W/m/K)
Conductivity tensor Kyy (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
kz — Conductivity tensor Kzz (W/m/K)
Conductivity tensor Kzz (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
kxy — Symmetric coupling Kxy (W/m/K)
Symmetric coupling Kxy (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
kxz — Symmetric coupling Kxz (W/m/K)
Symmetric coupling Kxz (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
kyz — Symmetric coupling Kyz (W/m/K)
Symmetric coupling Kyz (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
grad — Temperature gradient x y z (K/m)
Three signed spatial temperature derivatives in the same orthonormal coordinate frame as the conductivity tensor. Use comma-separated values in the stated order.
normal — Surface normal x y z
Three components defining the surface orientation. Any nonzero vector is normalized before projection. Use comma-separated values in the stated order.

Interpreting the result

Local homogeneous linear conductivity tensor at the state of interest. Does not solve the surrounding temperature field or rotate a tensor automatically from material axes.

Reading the outputs

All flux components and normal projection use W/m². A negative normal flux enters the face relative to the chosen outward normal.

Frequently asked questions

Must heat flow be parallel to the negative temperature gradient?

Not in an anisotropic material; off-diagonal couplings or unequal principal conductivities can rotate the flux.

Why reject an indefinite tensor?

It would permit conductive heat flow up a temperature gradient in some direction, violating the passive model.

Can I enter a normal vector longer than one?

Yes. The tool normalizes it; only direction affects projected flux.

How do I use the Anisotropic conductivity tensor heat flux direction calculator?

Enter Conductivity tensor Kxx (W/m/K), Conductivity tensor Kyy (W/m/K), Conductivity tensor Kzz (W/m/K), Symmetric coupling Kxy (W/m/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Anisotropic conductivity tensor heat flux direction?

Conductivity tensor Kxx (W/m/K) = 10; Conductivity tensor Kyy (W/m/K) = 2; Conductivity tensor Kzz (W/m/K) = 1; Symmetric coupling Kxy (W/m/K) = 1; Symmetric coupling Kxz (W/m/K) = 0; Symmetric coupling Kyz (W/m/K) = 0; Temperature gradient x y z (K/m) = [100, 20, 0]; Surface normal x y z = [1, 0, 0]. Heat flux component x: -1020 W/m² Heat flux component y: -140 W/m² Heat flux component z: 0 W/m² Heat flux through oriented surface: -1020 W/m² For Kxx=10, Kyy=2, Kzz=1 and Kxy=1 W/m/K, a gradient [100,20,0] K/m gives flux [−1,020,−140,0] W/m². The nonparallel vectors show why a scalar conductivity cannot capture the entered cross-coupling.