How to use this calculator
Plan a battery bank’s series and parallel counts to meet a target voltage and amp-hour capacity.
- Enter Single battery nominal voltage (V), Single battery capacity (Ah), Target bank voltage (V), Required bank capacity (Ah). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Series connections add voltage while preserving amp-hours; parallel strings add capacity while keeping voltage constant. The calculator rounds the string count up so the requested capacity is met.
Inputs and units
unitV— Single battery nominal voltage (V)- Use the battery’s nominal DC voltage.
unitAh— Single battery capacity (Ah)- Capacity of one battery at its stated rating.
targetV— Target bank voltage (V)- Must be a whole-number multiple of unit voltage.
targetAh— Required bank capacity (Ah)- Minimum desired amp-hour capacity.
Formula
Series batteries = target voltage ÷ unit voltage; parallel strings = ceil(target Ah ÷ unit Ah); total batteries = series × parallel.
Worked example
Four 12 V, 100 Ah batteries in series make 48 V and 100 Ah. Three parallel strings meet a 250 Ah target, requiring 12 batteries and providing 300 Ah nominally.
Assumptions and limits
Nominal capacity ignores discharge-rate effects, temperature, depth-of-discharge limits, wiring losses, fuse ratings, and charge-controller compatibility.
Frequently asked questions
Why can capacity exceed the target?
Parallel strings must be whole batteries, so the string count is rounded upward.
Can battery types be mixed in a bank?
This arithmetic does not validate mixing chemistries, ages, or models; follow manufacturer guidance.
Does it size conductors or fuses?
No. Electrical protection and cable design require separate current and installation checks.
How do I use the Battery bank series-parallel configuration calculator?
Enter Single battery nominal voltage (V), Single battery capacity (Ah), Target bank voltage (V), Required bank capacity (Ah). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Battery bank series-parallel configuration?
Four 12 V, 100 Ah batteries in series make 48 V and 100 Ah. Three parallel strings meet a 250 Ah target, requiring 12 batteries and providing 300 Ah nominally.
Read our calculation methodology.