How to use this calculator
Assess how phase mismatch limits coherent buildup along a uniform nonlinear optical interaction, without assuming a material conversion coefficient.
- Enter Interaction length (mm), Wavevector mismatch (radians/mm). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Coherent nonlinear conversion phase mismatch acceptance explained
A uniform nonlinear interaction adds generated field amplitude along its length. When phase mismatch accumulates, later portions can cancel earlier ones; the squared sinc factor reports relative power acceptance against perfect phase matching.
Inputs, symbols, and units
length— Interaction length (mm)- Uniform nonlinear interaction length.
mismatch— Wavevector mismatch (radians/mm)- Signed difference between generated and driving nonlinear-polarization wavevectors.
Formula and method
A∝∫₀ᴸexp(iΔkz)dz; normalized power=sinc²(ΔkL/2); effective L²=L²sinc²(ΔkL/2).
This is the undepleted uniform plane-wave phase-matching factor common to coherent three-wave buildup. It gives relative acceptance only, not absolute second-harmonic output power.
A worked scenario
Interaction length (mm) = 5; Wavevector mismatch (radians/mm) = 0.5.
- Normalized coherent conversion factor: 0.576366
- Half length phase mismatch: 1.25 radians
- Coherent effective length squared: 14.409149 mm²
For a 5 mm interaction, mismatch 2π/5 rad/mm makes one complete relative phase turn and ideally cancels the generated amplitude.
Assumptions and edge cases
No pump depletion, focusing, walk-off, absorption, quasi-phase-matching domains or nonlinear coefficient. Absolute conversion requires the actual coupled-wave model.
Reading the outputs
The normalized conversion factor is a fraction, half-length phase is radians and coherent length squared is mm².
Frequently asked questions
Why can a longer medium generate less relative output?
Oppositely phased portions of the driven field can cancel.
Does a factor of one mean 100-percent conversion?
No. It means perfect phase matching relative to the same undepleted interaction.
Does changing mismatch sign change the factor?
No. The squared sinc acceptance is even.
How do I use the Coherent nonlinear conversion phase mismatch acceptance calculator?
Enter Interaction length (mm), Wavevector mismatch (radians/mm). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Coherent nonlinear conversion phase mismatch acceptance?
Interaction length (mm) = 5; Wavevector mismatch (radians/mm) = 0.5. Normalized coherent conversion factor: 0.576366 Half length phase mismatch: 1.25 radians Coherent effective length squared: 14.409149 mm² For a 5 mm interaction, mismatch 2π/5 rad/mm makes one complete relative phase turn and ideally cancels the generated amplitude.
Background or definition reference: Original integrated nonlinear-optics phase-matching study.
Read our calculation methodology.