How to use this calculator
Estimate self-phase modulation accumulated by a known optical intensity while accounting for uniform power attenuation.
- Enter Nonlinear index n2 (m²/W), Input on axis intensity (GW/cm²), Material length (mm), Power attenuation coefficient (per m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Kerr nonlinear phase through an attenuating medium explained
A numerical walkthrough
Nonlinear index n2 (m²/W) = 2.60000000e-20; Input on axis intensity (GW/cm²) = 1; Material length (mm) = 10; Power attenuation coefficient (per m) = 0; Vacuum wavelength (nm) = 800.
- Accumulated Kerr phase B integral: 0.02042 radians
- Effective nonlinear length: 10 mm
- Exit to entrance intensity ratio: 1
At 800 nm, n2=2.6×10⁻²⁰ m²/W and 1 GW/cm² across 10 mm give about 0.0204 rad of nonlinear phase with no attenuation.
The model behind the numbers
B=(2π/λ)n₂ I₀ Leff; Leff=∫₀ᴸ exp(−αz)dz=(1−exp(−αL))/α.
The phase follows the on-axis peak intensity. n2 uses the convention Δn=n2 I. Effective length uses power attenuation, not field-amplitude attenuation.
What to enter
n2— Nonlinear index n2 (m²/W)- Signed instantaneous Kerr intensity coefficient.
intensity— Input on axis intensity (GW/cm²)- Peak intensity before propagation.
length— Material length (mm)- Propagation distance.
loss— Power attenuation coefficient (per m)- Exponential intensity attenuation coefficient.
wavelength— Vacuum wavelength (nm)- Monochromatic vacuum wavelength in nanometres.
Interpreting the result
Fixed transverse profile and negligible pulse reshaping. Self-focusing, dispersion, saturation and two-photon absorption are excluded.
Reading the outputs
B is signed radians, effective length is mm and the final output is remaining intensity fraction.
Frequently asked questions
Does a large B value specify a safe operating limit?
No. Acceptable distortion depends on the application and spatial-temporal profile.
Can n2 be negative?
Yes. Its sign reverses the nonlinear phase.
Why does attenuation shorten the effective length?
The Kerr phase is weighted by the declining local intensity.
How do I use the Kerr nonlinear phase through an attenuating medium calculator?
Enter Nonlinear index n2 (m²/W), Input on axis intensity (GW/cm²), Material length (mm), Power attenuation coefficient (per m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Kerr nonlinear phase through an attenuating medium?
Nonlinear index n2 (m²/W) = 2.60000000e-20; Input on axis intensity (GW/cm²) = 1; Material length (mm) = 10; Power attenuation coefficient (per m) = 0; Vacuum wavelength (nm) = 800. Accumulated Kerr phase B integral: 0.02042 radians Effective nonlinear length: 10 mm Exit to entrance intensity ratio: 1 At 800 nm, n2=2.6×10⁻²⁰ m²/W and 1 GW/cm² across 10 mm give about 0.0204 rad of nonlinear phase with no attenuation.
Background or definition reference: MIT Ultrafast Optics, pulse propagation and characterization.
Read our calculation methodology.