How to use this calculator
Reduce constant-head and falling-head laboratory observations to hydraulic conductivity on one page, with both tests clearly separated.
- Enter Specimen cross-section (cm²), Specimen length (cm), Collected constant-head volume (cm³), Constant test head (cm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Constant and falling head soil permeability test explained
Constant-head and falling-head permeability tests infer hydraulic conductivity from different observations. This page evaluates both datasets independently in the same specimen geometry; use the result for the test that was actually performed rather than averaging the two estimates.
Inputs, symbols, and units
A— Specimen cross-section (cm²)- Area normal to laboratory flow.
L— Specimen length (cm)- Drainage length through the specimen.
V— Collected constant-head volume (cm³)- Water collected during t under the fixed head H; this is a separate constant-head result.
H— Constant test head (cm)- Hydraulic head difference across the specimen during volume collection.
t— Elapsed test time (s)- Duration used by both reported test interpretations.
a— Falling-head standpipe area (cm²)- Cross-section of the standpipe connected to the specimen.
h1— Initial falling head (cm)- Starting head difference for the falling-head interpretation.
h2— Final falling head (cm)- Final head difference; it must not exceed h1.
Formula and method
Constant head k=VL/(AHt); falling head k=aL ln(h1/h2)/(At). Geometric cm units produce cm/s, converted to m/s.
The tests are alternative interpretations of different measurements. Their outputs are not averaged, and a temperature correction is not silently assumed.
A worked scenario
Specimen cross-section (cm²) = 50; Specimen length (cm) = 15; Collected constant-head volume (cm³) = 150; Constant test head (cm) = 30; Elapsed test time (s) = 120; Falling-head standpipe area (cm²) = 1; Initial falling head (cm) = 60; Final falling head (cm) = 20.
- Constant-head conductivity: 0.000125 m/s
- Falling-head conductivity: 0.000027 m/s
A 50 cm² specimen 15 cm long collects 150 cm³ in 120 s at 30 cm constant head. A separate 1 cm² standpipe falls from 60 to 20 cm over the same stated duration.
Assumptions and edge cases
Saturated laminar Darcy flow, no leakage, constant specimen geometry and negligible system losses. Sample disturbance and water viscosity variation are excluded. Educational model; this is not a code-compliant design check.
Reading the outputs
Both reported conductivities are in m/s; use only the test whose observations were actually collected.
Frequently asked questions
Can I compare both values from one set of readings?
Only if both complete test datasets were measured; placeholder values do not establish a second test.
Why does equal initial and final falling head give zero k?
No measurable head decline occurred during the interval under this ideal test.
Is hydraulic conductivity an intrinsic material constant?
It depends on fluid viscosity/density as well as pore structure; temperature and fluid type matter.
How do I use the Constant and falling head soil permeability test calculator?
Enter Specimen cross-section (cm²), Specimen length (cm), Collected constant-head volume (cm³), Constant test head (cm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Constant and falling head soil permeability test?
Specimen cross-section (cm²) = 50; Specimen length (cm) = 15; Collected constant-head volume (cm³) = 150; Constant test head (cm) = 30; Elapsed test time (s) = 120; Falling-head standpipe area (cm²) = 1; Initial falling head (cm) = 60; Final falling head (cm) = 20. Constant-head conductivity: 0.000125 m/s Falling-head conductivity: 0.000027 m/s A 50 cm² specimen 15 cm long collects 150 cm³ in 120 s at 30 cm constant head. A separate 1 cm² standpipe falls from 60 to 20 cm over the same stated duration.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume I.
Read our calculation methodology.