How to use this calculator
Upscale several horizontal soil layers into equivalent conductivities parallel and perpendicular to layering.
- Enter Layer thicknesses (m), Layer hydraulic conductivities (m/s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Layered soil equivalent hydraulic anisotropy explained
Upscale several horizontal soil layers into equivalent conductivities parallel and perpendicular to layering.
How the calculation works
kh=ΣHiki/ΣHi; kv=ΣHi/Σ(Hi/ki); anisotropy=kh/kv.
Parallel layers carry additive flows under a common gradient, whereas perpendicular flow crosses additive hydraulic resistances. This is why the arithmetic and harmonic means differ.
Set up the calculation
H— Layer thicknesses (m)- Positive thickness of every continuous horizontal layer. Use comma-separated values in the stated order.
k— Layer hydraulic conductivities (m/s)- Positive saturated conductivities matched to the layer thicknesses. Use comma-separated values in the stated order.
Limits of this model
Continuous horizontal layers, saturated steady Darcy flow and negligible interface resistance. Discontinuous lenses and preferential channels need multidimensional analysis. Educational model; this is not a code-compliant design check.
Check this example
Layer thicknesses (m) = [1, 2, 1]; Layer hydraulic conductivities (m/s) = [0.0001, 1e-06, 1e-05].
- Parallel equivalent conductivity: 0.000028 m/s
- Perpendicular equivalent conductivity: 0.000002 m/s
- Anisotropy ratio kh/kv: 14.77
Layers 1, 2 and 1 m thick have conductivities 10⁻⁴, 10⁻⁶ and 10⁻⁵ m/s. The low-conductivity middle layer strongly reduces perpendicular flow.
Reading the outputs
Two conductivities are m/s; their ratio is dimensionless and is at least one for positive isotropic layer conductivities.
Frequently asked questions
Why does a thin tight layer matter so much vertically?
Vertical flow must cross that layer in series, so its hydraulic resistance can dominate.
Can zero conductivity be entered?
No. An impermeable barrier is a limiting zero-flow case with an infinite resistance, outside the finite calculation.
What if all k values are equal?
Both equivalent values equal that common k and the anisotropy ratio is one.
How do I use the Layered soil equivalent hydraulic anisotropy calculator?
Enter Layer thicknesses (m), Layer hydraulic conductivities (m/s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Layered soil equivalent hydraulic anisotropy?
Layer thicknesses (m) = [1, 2, 1]; Layer hydraulic conductivities (m/s) = [0.0001, 1e-06, 1e-05]. Parallel equivalent conductivity: 0.000028 m/s Perpendicular equivalent conductivity: 0.000002 m/s Anisotropy ratio kh/kv: 14.77 Layers 1, 2 and 1 m thick have conductivities 10⁻⁴, 10⁻⁶ and 10⁻⁵ m/s. The low-conductivity middle layer strongly reduces perpendicular flow.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume I.
Read our calculation methodology.