How to use this calculator
Predict conversion in an ideal isothermal plug-flow reactor for a single irreversible power-law reaction.
- Enter Feed reactant concentration (mol/L), Rate constant consistent with order and minutes, Reaction order, Nominal residence time (min). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Constant density power law plug flow reactor explained
An ideal plug-flow element experiences the reaction rate along its residence time as concentration changes. Reaction order determines the integrated concentration curve; for order below one, this model reaches zero concentration after a finite time.
Inputs, symbols, and units
c— Feed reactant concentration (mol/L)- Feed reactant concentration (mol/L).
k— Rate constant consistent with order and minutes- Rate constant consistent with order and minutes.
n— Reaction order- Reaction order.
t— Nominal residence time (min)- Nominal residence time (min).
Formula and method
dC/dτ=−kCⁿ; integrated power-law concentration
A fluid element obeys dC/dtau=−kCⁿ under constant-density plug flow. Use the exponential solution at order one and the integrated power-law expression otherwise. For order below one, stop at complete depletion instead of raising a negative concentration expression to a fractional power.
A worked scenario
Feed reactant concentration (mol/L) = 1; Rate constant consistent with order and minutes = 0.1; Reaction order = 1; Nominal residence time (min) = 10.
- Reactant conversion: 0.63212056
- Outlet concentration: 0.36787944 mol/L
This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Assumptions and edge cases
Constant density and volume flow. Rate constant units are (mol/L)^(1−n)/min; changing order changes the required units. Finite depletion is capped at zero concentration for n<1.
Frequently asked questions
Is this a mixed reactor?
No, fluid elements follow a plug-flow concentration history.
Can the same numeric k be compared across orders?
Only after accounting for its different units and fitted model.
Does it model equilibrium reversal?
No.
How do I use the Constant density power law plug flow reactor calculator?
Enter Feed reactant concentration (mol/L), Rate constant consistent with order and minutes, Reaction order, Nominal residence time (min). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Constant density power law plug flow reactor?
Feed reactant concentration (mol/L) = 1; Rate constant consistent with order and minutes = 0.1; Reaction order = 1; Nominal residence time (min) = 10. Reactant conversion: 0.63212056 Outlet concentration: 0.36787944 mol/L This scenario uses the stated units and assumptions. Displayed values are rounded only after calculation.
Method reference: University of Michigan reaction-engineering design notes.
Read our calculation methodology.