CalcWorldHub
Free online calculator · no signup

Discrete unit hydrograph rainfall excess convolution calculator

Transform a sequence of effective-rainfall depths into a direct-runoff hydrograph through discrete superposition.

4,000 tools
Discrete unit hydrograph rainfall excess convolution calculator — Effective rainfall pulses (mm), One millimetre unit hydrograph ordinates (m³/s/mm), Common pulse and ordinate interval (s) and calculation method
Discrete unit hydrograph rainfall excess convolution calculator: inputs and calculation method.

How to use this calculator

Transform a sequence of effective-rainfall depths into a direct-runoff hydrograph through discrete superposition.

  1. Enter Effective rainfall pulses (mm), One millimetre unit hydrograph ordinates (m³/s/mm), Common pulse and ordinate interval (s). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Discrete unit hydrograph rainfall excess convolution explained

Each effective-rainfall pulse is multiplied by the unit-hydrograph ordinate at its lag; summing the shifted responses produces the sampled direct-runoff hydrograph. Rainfall pulses and ordinates must use the same time interval.

Peak direct runoff16.7m³/s
Peak direct runoff: 16.7 m³/s in the worked scenario.

Inputs, symbols, and units

P — Effective rainfall pulses (mm)
Runoff-producing rainfall depths per uniform pulse duration, after losses. Use comma-separated values in the stated order.
U — One millimetre unit hydrograph ordinates (m³/s/mm)
Response to one millimetre excess rainfall of the same pulse duration; baseflow excluded. Use comma-separated values in the stated order.
dt — Common pulse and ordinate interval (s)
Time spacing of both the rainfall pulses and unit-hydrograph samples.

Formula and method

Qk=ΣPiUk−i, where Pi is rainfall excess in mm and U is discharge per mm for the same pulse duration.

The unit hydrograph duration must match the effective-rainfall pulse width. The algorithm shifts and adds response ordinates, then integrates the resulting sampled discharge.

A worked scenario

Effective rainfall pulses (mm) = [5, 12, 3]; One millimetre unit hydrograph ordinates (m³/s/mm) = [0, 0.4, 1, 0.7, 0.3, 0]; Common pulse and ordinate interval (s) = 1800.

  • Peak direct runoff: 16.7 m³/s
  • Time of sampled runoff peak: 5400 s
  • Integrated direct-runoff volume: 86400 m³
  • Total effective rainfall: 20 mm

Excess-rainfall pulses of 5, 12 and 3 mm at 30-minute spacing are convolved with unit ordinates 0, 0.4, 1, 0.7, 0.3 and 0 m³/s/mm.

Assumptions and edge cases

Linear time-invariant response and rainfall spatially compatible with the unit hydrograph. No baseflow, changing losses or duration conversion is inferred. Educational model; this is not a code-compliant design check.

Reading the outputs

Peak discharge is m³/s, peak-time offset is seconds, runoff volume is m³ and total rainfall excess is mm.

Frequently asked questions

Can total rainfall be entered directly?

Only if it already equals effective runoff-producing rainfall; infiltration and other losses must otherwise be removed first.

Why must durations match?

A unit hydrograph represents one specified rainfall duration; using a different pulse width changes the physical convolution.

Does the integrated volume validate the unit hydrograph?

It can reveal an inconsistent normalization, but catchment area and a complete response tail are needed for a full unit-volume check.

How do I use the Discrete unit hydrograph rainfall excess convolution calculator?

Enter Effective rainfall pulses (mm), One millimetre unit hydrograph ordinates (m³/s/mm), Common pulse and ordinate interval (s). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Discrete unit hydrograph rainfall excess convolution?

Effective rainfall pulses (mm) = [5, 12, 3]; One millimetre unit hydrograph ordinates (m³/s/mm) = [0, 0.4, 1, 0.7, 0.3, 0]; Common pulse and ordinate interval (s) = 1800. Peak direct runoff: 16.7 m³/s Time of sampled runoff peak: 5400 s Integrated direct-runoff volume: 86400 m³ Total effective rainfall: 20 mm Excess-rainfall pulses of 5, 12 and 3 mm at 30-minute spacing are convolved with unit ordinates 0, 0.4, 1, 0.7, 0.3 and 0 m³/s/mm.