How to use this calculator
Transform a sequence of effective-rainfall depths into a direct-runoff hydrograph through discrete superposition.
- Enter Effective rainfall pulses (mm), One millimetre unit hydrograph ordinates (m³/s/mm), Common pulse and ordinate interval (s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Discrete unit hydrograph rainfall excess convolution explained
Each effective-rainfall pulse is multiplied by the unit-hydrograph ordinate at its lag; summing the shifted responses produces the sampled direct-runoff hydrograph. Rainfall pulses and ordinates must use the same time interval.
Inputs, symbols, and units
P— Effective rainfall pulses (mm)- Runoff-producing rainfall depths per uniform pulse duration, after losses. Use comma-separated values in the stated order.
U— One millimetre unit hydrograph ordinates (m³/s/mm)- Response to one millimetre excess rainfall of the same pulse duration; baseflow excluded. Use comma-separated values in the stated order.
dt— Common pulse and ordinate interval (s)- Time spacing of both the rainfall pulses and unit-hydrograph samples.
Formula and method
Qk=ΣPiUk−i, where Pi is rainfall excess in mm and U is discharge per mm for the same pulse duration.
The unit hydrograph duration must match the effective-rainfall pulse width. The algorithm shifts and adds response ordinates, then integrates the resulting sampled discharge.
A worked scenario
Effective rainfall pulses (mm) = [5, 12, 3]; One millimetre unit hydrograph ordinates (m³/s/mm) = [0, 0.4, 1, 0.7, 0.3, 0]; Common pulse and ordinate interval (s) = 1800.
- Peak direct runoff: 16.7 m³/s
- Time of sampled runoff peak: 5400 s
- Integrated direct-runoff volume: 86400 m³
- Total effective rainfall: 20 mm
Excess-rainfall pulses of 5, 12 and 3 mm at 30-minute spacing are convolved with unit ordinates 0, 0.4, 1, 0.7, 0.3 and 0 m³/s/mm.
Assumptions and edge cases
Linear time-invariant response and rainfall spatially compatible with the unit hydrograph. No baseflow, changing losses or duration conversion is inferred. Educational model; this is not a code-compliant design check.
Reading the outputs
Peak discharge is m³/s, peak-time offset is seconds, runoff volume is m³ and total rainfall excess is mm.
Frequently asked questions
Can total rainfall be entered directly?
Only if it already equals effective runoff-producing rainfall; infiltration and other losses must otherwise be removed first.
Why must durations match?
A unit hydrograph represents one specified rainfall duration; using a different pulse width changes the physical convolution.
Does the integrated volume validate the unit hydrograph?
It can reveal an inconsistent normalization, but catchment area and a complete response tail are needed for a full unit-volume check.
How do I use the Discrete unit hydrograph rainfall excess convolution calculator?
Enter Effective rainfall pulses (mm), One millimetre unit hydrograph ordinates (m³/s/mm), Common pulse and ordinate interval (s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Discrete unit hydrograph rainfall excess convolution?
Effective rainfall pulses (mm) = [5, 12, 3]; One millimetre unit hydrograph ordinates (m³/s/mm) = [0, 0.4, 1, 0.7, 0.3, 0]; Common pulse and ordinate interval (s) = 1800. Peak direct runoff: 16.7 m³/s Time of sampled runoff peak: 5400 s Integrated direct-runoff volume: 86400 m³ Total effective rainfall: 20 mm Excess-rainfall pulses of 5, 12 and 3 mm at 30-minute spacing are convolved with unit ordinates 0, 0.4, 1, 0.7, 0.3 and 0 m³/s/mm.
Read our calculation methodology.