CalcWorldHub
Free online calculator · no signup

Nash reservoir cascade instantaneous runoff response calculator

Evaluate an ideal instantaneous catchment response represented by a cascade of identical linear reservoirs.

4,000 tools
Nash reservoir cascade instantaneous runoff response calculator — Number of identical linear reservoirs, Each reservoir storage coefficient (hours), Time after instantaneous rainfall excess (hours) and calculation method
Nash reservoir cascade instantaneous runoff response calculator: inputs and calculation method.

How to use this calculator

Evaluate an ideal instantaneous catchment response represented by a cascade of identical linear reservoirs.

  1. Enter Number of identical linear reservoirs, Each reservoir storage coefficient (hours), Time after instantaneous rainfall excess (hours), Instantaneous effective rainfall depth (mm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Nash reservoir cascade instantaneous runoff response explained

Instantaneous direct runoff rate5.4901m³/s
Instantaneous direct runoff rate: 5.49005 m³/s in the worked scenario.

How the calculation works

u(t)=t^(n−1)e^(−t/K)/(K^n Γ(n)); Q=Vexcess u(t); cumulative fraction is the gamma CDF; tpeak=(n−1)K.

The cascade supplies a response shape from n and K. It differs from a finite-duration measured unit hydrograph and must be integrated over rainfall pulses before modeling a real storm.

Set up the calculation

n — Number of identical linear reservoirs
Integer cascade order defining the gamma impulse response. Enter a whole number.
K — Each reservoir storage coefficient (hours)
Linear reservoir time constant shared by every cascade stage.
t — Time after instantaneous rainfall excess (hours)
Elapsed time from an ideal spatially uniform impulse.
P — Instantaneous effective rainfall depth (mm)
Total impulse depth converted to runoff volume.
A — Catchment area (km²)
Catchment plan area associated with the response.

Limits of this model

Linear cascade, integer order and instantaneous effective rainfall. It is not a calibrated rainfall-loss model or a finite-duration storm hydrograph. Educational model; this is not a code-compliant design check.

Check this example

Number of identical linear reservoirs = 3; Each reservoir storage coefficient (hours) = 1.5; Time after instantaneous rainfall excess (hours) = 4; Instantaneous effective rainfall depth (mm) = 10; Catchment area (km²) = 12.

  • Instantaneous direct runoff rate: 5.49005 m³/s
  • Cumulative runoff fraction: 49.817507 %
  • Impulse response peak time: 3 hours

Three reservoirs with K=1.5 h represent a 12 km² catchment receiving an ideal 10 mm instantaneous excess pulse. The response peaks 3 h after the impulse.

Reading the outputs

Discharge is m³/s, completed runoff volume fraction is percent and the ideal impulse peak time is hours.

Source

Nash, J. E. (1957), “The form of the instantaneous unit hydrograph,” NERC Open Research Archive. The original source motivates the instantaneous unit hydrograph; this calculator uses an integer cascade of identical linear reservoirs.

Frequently asked questions

Can n be fractional?

The broader gamma model can allow it, but this implementation restricts n to an actual integer reservoir cascade.

Why is the n=1 response nonzero at time zero?

A single linear reservoir has an immediate exponentially decaying impulse response.

Does the cumulative percentage include baseflow?

No. It is only the fraction of the modeled rainfall-excess impulse volume released.

How do I use the Nash reservoir cascade instantaneous runoff response calculator?

Enter Number of identical linear reservoirs, Each reservoir storage coefficient (hours), Time after instantaneous rainfall excess (hours), Instantaneous effective rainfall depth (mm), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Nash reservoir cascade instantaneous runoff response?

Number of identical linear reservoirs = 3; Each reservoir storage coefficient (hours) = 1.5; Time after instantaneous rainfall excess (hours) = 4; Instantaneous effective rainfall depth (mm) = 10; Catchment area (km²) = 12. Instantaneous direct runoff rate: 5.49005 m³/s Cumulative runoff fraction: 49.817507 % Impulse response peak time: 3 hours Three reservoirs with K=1.5 h represent a 12 km² catchment receiving an ideal 10 mm instantaneous excess pulse. The response peaks 3 h after the impulse.