CalcWorldHub
Free online calculator · no signup

Modified Puls nonlinear reservoir event routing calculator

Route an inflow hydrograph through a constant-area reservoir with a nonlinear square-root outlet using the level-pool storage-indication equation.

4,000 tools
Modified Puls nonlinear reservoir event routing calculator — Inflow ordinates (m³/s), Routing time step (s), Constant reservoir plan area (m²) and calculation method
Modified Puls nonlinear reservoir event routing calculator: inputs and calculation method.

How to use this calculator

Route an inflow hydrograph through a constant-area reservoir with a nonlinear square-root outlet using the level-pool storage-indication equation.

  1. Enter Inflow ordinates (m³/s), Routing time step (s), Constant reservoir plan area (m²), Outlet rating coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Modified Puls nonlinear reservoir event routing explained

Route inflow through a level-pool reservoir by solving the Modified Puls storage balance at each time step.

Maximum routed water level1.4954m
Maximum routed water level: 1.495405 m in the worked scenario.

How the calculation works

2S2/Δt+O2=I1+I2+2S1/Δt−O1, with S=Az and O=C√z.

Trapezoidal inflow/outflow integration conserves event volume at each step. The level and outlet rating are solved together rather than clipping an independently computed outflow.

Set up the calculation

I — Inflow ordinates (m³/s)
Equally spaced inflows including the starting and final ordinates. Use comma-separated values in the stated order.
dt — Routing time step (s)
Time interval between all inflow ordinates.
A — Constant reservoir plan area (m²)
Storage is S=A z above the zero-outflow level.
C — Outlet rating coefficient
Coefficient in O=C√z, with O in m³/s and z in m.
z0 — Initial reservoir level above outlet datum (m)
Starting storage elevation used to initialize outflow consistently.

Limits of this model

Level-pool storage, constant plan area and one monotonic outlet rating. Spillway transitions, backwater and a final recession longer than the supplied event require added modeling/ordinates. Educational model; this is not a code-compliant design check.

Check this example

Inflow ordinates (m³/s) = [0, 4, 10, 6, 2, 0, 0]; Routing time step (s) = 300; Constant reservoir plan area (m²) = 3000; Outlet rating coefficient = 2; Initial reservoir level above outlet datum (m) = 0.

  • Maximum routed water level: 1.495405 m
  • Maximum routed outflow: 2.445735 m³/s
  • Final water level: 1.133693 m
  • Final outflow: 2.129501 m³/s

Inflow ordinates 0, 4, 10, 6, 2, 0 and 0 m³/s at five-minute spacing enter a 3000 m² reservoir with O=2√z and initially empty active storage.

Independent stepwise balance gives a maximum level of 1.495405 m and maximum outflow of 2.445735 m³/s for this five-minute routing step.

Reading the outputs

Maximum and final levels are m above the outlet datum; peak and final outflows are m³/s.

Frequently asked questions

Why might a large time step be rejected?

Trapezoidal routing can demand more outflow volume than available storage; refining the event step avoids an unphysical negative stage.

Does the last input mark complete drainage?

No. Add a sufficiently long recession tail if the reservoir still holds water at the last ordinate.

Can I enter an arbitrary storage curve?

Not here. Storage is explicitly linear in stage; a varying-area reservoir needs a tabulated storage-indication model.

How do I use the Modified Puls nonlinear reservoir event routing calculator?

Enter Inflow ordinates (m³/s), Routing time step (s), Constant reservoir plan area (m²), Outlet rating coefficient, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Modified Puls nonlinear reservoir event routing?

Inflow ordinates (m³/s) = [0, 4, 10, 6, 2, 0, 0]; Routing time step (s) = 300; Constant reservoir plan area (m²) = 3000; Outlet rating coefficient = 2; Initial reservoir level above outlet datum (m) = 0. Maximum routed water level: 1.495405 m Maximum routed outflow: 2.445735 m³/s Final water level: 1.133693 m Final outflow: 2.129501 m³/s Inflow ordinates 0, 4, 10, 6, 2, 0 and 0 m³/s at five-minute spacing enter a 3000 m² reservoir with O=2√z and initially empty active storage. Independent stepwise balance gives a maximum level of 1.495405 m and maximum outflow of 2.445735 m³/s for this five-minute routing step.