Variable head tank gravity drain duration calculator

Integrate a tank’s declining gravity discharge as water head falls, instead of dividing volume by the initial flow rate.

4,000 tools
Variable head tank gravity drain duration calculator — Tank horizontal area (m²), Outlet opening area (m²), Outlet discharge coefficient and calculation method
Variable head tank gravity drain duration calculator: inputs and calculation method.

How to use this calculator

Integrate a tank’s declining gravity discharge as water head falls, instead of dividing volume by the initial flow rate.

  1. Enter Tank horizontal area (m²), Outlet opening area (m²), Outlet discharge coefficient, Initial water head (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Variable head tank gravity drain duration explained

Integrating Torricelli discharge as tank head falls gives the time between two specified water levels.

Gravity draining duration517.5905s
Gravity draining duration: 517.590516 s in the worked scenario.

How the calculation works

A dh/dt=−Cd a√(2gh); t=2A(√h1−√h2)/(Cd a√(2g)).

Head is measured above outlet centre. The initial rate declines continuously, so using it as a constant flow underestimates the draining time.

Set up the calculation

A — Tank horizontal area (m²)
Constant plan area of the reservoir.
a — Outlet opening area (m²)
Fixed small outlet area whose centre defines the water-head datum.
Cd — Outlet discharge coefficient
Constant effective contraction/loss coefficient.
h1 — Initial water head (m)
Initial free surface above outlet centre.
h2 — Final water head (m)
Target free surface above outlet centre, no greater than the initial head.

Limits of this model

Large constant-area vented tank, small fixed outlet, constant Cd, no inflow or outlet submergence. Vortexing and final residual water are not predicted. Educational model; this is not a code-compliant design check.

Check this example

Tank horizontal area (m²) = 12; Outlet opening area (m²) = 0.02; Outlet discharge coefficient = 0.62; Initial water head (m) = 3; Final water head (m) = 0.3.

  • Gravity draining duration: 517.590516 s
  • Water volume released: 32.4 m³
  • Initial outlet discharge: 0.095117 m³/s

A 12 m² tank drains through a 0.02 m² outlet with Cd=0.62 from 3 m to 0.3 m head, releasing 32.4 m³.

Reading the outputs

Duration is seconds, released volume is m³ and the initial instantaneous discharge is m³/s.

Frequently asked questions

Can the final head be zero?

Yes. The ideal integral is finite, though real outlet geometry and residual water affect the last part of draining.

Can this model an unvented tank?

No. Gas pressure changes would alter the driving head.

Why require tank area larger than outlet area?

The approximation assumes negligible tank-surface velocity compared with outlet velocity.

How do I use the Variable head tank gravity drain duration calculator?

Enter Tank horizontal area (m²), Outlet opening area (m²), Outlet discharge coefficient, Initial water head (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Variable head tank gravity drain duration?

Tank horizontal area (m²) = 12; Outlet opening area (m²) = 0.02; Outlet discharge coefficient = 0.62; Initial water head (m) = 3; Final water head (m) = 0.3. Gravity draining duration: 517.590516 s Water volume released: 32.4 m³ Initial outlet discharge: 0.095117 m³/s A 12 m² tank drains through a 0.02 m² outlet with Cd=0.62 from 3 m to 0.3 m head, releasing 32.4 m³.