How to use this calculator
Translate and attenuate a sampled flood hydrograph through one calibrated linear Muskingum reach.
- Enter Upstream inflow ordinates (m³/s), Reach storage travel coefficient (s), Inflow weighting factor, Hydrograph time step (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Muskingum flood reach routing explained
A numerical walkthrough
Upstream inflow ordinates (m³/s) = [5, 10, 25, 40, 25, 10, 5, 5, 5]; Reach storage travel coefficient (s) = 900; Inflow weighting factor = 0.2; Hydrograph time step (s) = 600; Initial downstream outflow (m³/s) = 5.
- Peak downstream outflow: 30.233414 m³/s
- Final downstream outflow: 6.822481 m³/s
- Time of sampled peak: 2400 s
- Current-inflow routing coefficient: 0.117647
A hydrograph peaking at 40 m³/s is routed with K=900 s, X=0.2 and a 600 s interval, starting from 5 m³/s downstream flow.
The model behind the numbers
Oj=C0Ij+C1Ij−1+C2Oj−1; coefficients follow trapezoidal continuity and S=K[XI+(1−X)O].
The allowed time-step interval keeps all three recurrence coefficients nonnegative. K and X must be calibrated or justified for the reach and event range.
What to enter
I— Upstream inflow ordinates (m³/s)- Nonnegative inflow samples at equal time spacing. Use comma-separated values in the stated order.
K— Reach storage travel coefficient (s)- Calibrated linear storage time coefficient.
X— Inflow weighting factor- Weight in S=K[XI+(1−X)O].
dt— Hydrograph time step (s)- Must satisfy 2KX ≤ Δt ≤ 2K(1−X) for nonnegative routing coefficients.
O0— Initial downstream outflow (m³/s)- Outflow at the first inflow sample, reflecting the assumed initial reach storage.
Interpreting the result
Linear storage approximation for one reach. No backwater, floodplain exchange, lateral inflow or hydraulic geometry-based parameter estimation. Educational model; this is not a code-compliant design check.
Reading the outputs
Peak and final discharge are m³/s; time of peak is a sampled offset from the first ordinate, and C0 is dimensionless.
Frequently asked questions
Why can a small time step be invalid?
If Δt<2KX the current-inflow coefficient becomes negative, violating this nonnegative-coefficient implementation.
Is the peak time exact?
It is the largest sampled outflow time; interpolation between samples is not performed.
Can one K and X describe all floods?
Not necessarily. Overbank storage and nonlinear wave behavior can change effective routing parameters.
How do I use the Muskingum flood reach routing calculator?
Enter Upstream inflow ordinates (m³/s), Reach storage travel coefficient (s), Inflow weighting factor, Hydrograph time step (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Muskingum flood reach routing?
Upstream inflow ordinates (m³/s) = [5, 10, 25, 40, 25, 10, 5, 5, 5]; Reach storage travel coefficient (s) = 900; Inflow weighting factor = 0.2; Hydrograph time step (s) = 600; Initial downstream outflow (m³/s) = 5. Peak downstream outflow: 30.233414 m³/s Final downstream outflow: 6.822481 m³/s Time of sampled peak: 2400 s Current-inflow routing coefficient: 0.117647 A hydrograph peaking at 40 m³/s is routed with K=900 s, X=0.2 and a 600 s interval, starting from 5 m³/s downstream flow.
Background or definition reference: USACE HEC-HMS Technical Reference Manual, Muskingum Model.
The linked HEC-HMS page derives the recursive outflow relation from continuity and the Muskingum storage model; this calculator routes one reach from a specified initial outflow.
Read our calculation methodology.