CalcWorldHub
Free online calculator · no signup

Muskingum flood reach routing calculator

Translate and attenuate a sampled flood hydrograph through one calibrated linear Muskingum reach.

4,000 tools
Muskingum flood reach routing calculator — Upstream inflow ordinates (m³/s), Reach storage travel coefficient (s), Inflow weighting factor and calculation method
Muskingum flood reach routing calculator: inputs and calculation method.

How to use this calculator

Translate and attenuate a sampled flood hydrograph through one calibrated linear Muskingum reach.

  1. Enter Upstream inflow ordinates (m³/s), Reach storage travel coefficient (s), Inflow weighting factor, Hydrograph time step (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Muskingum flood reach routing explained

Peak downstream outflow30.2334m³/s
Peak downstream outflow: 30.233414 m³/s in the worked scenario.

A numerical walkthrough

Upstream inflow ordinates (m³/s) = [5, 10, 25, 40, 25, 10, 5, 5, 5]; Reach storage travel coefficient (s) = 900; Inflow weighting factor = 0.2; Hydrograph time step (s) = 600; Initial downstream outflow (m³/s) = 5.

  • Peak downstream outflow: 30.233414 m³/s
  • Final downstream outflow: 6.822481 m³/s
  • Time of sampled peak: 2400 s
  • Current-inflow routing coefficient: 0.117647

A hydrograph peaking at 40 m³/s is routed with K=900 s, X=0.2 and a 600 s interval, starting from 5 m³/s downstream flow.

The model behind the numbers

Oj=C0Ij+C1Ij−1+C2Oj−1; coefficients follow trapezoidal continuity and S=K[XI+(1−X)O].

The allowed time-step interval keeps all three recurrence coefficients nonnegative. K and X must be calibrated or justified for the reach and event range.

What to enter

I — Upstream inflow ordinates (m³/s)
Nonnegative inflow samples at equal time spacing. Use comma-separated values in the stated order.
K — Reach storage travel coefficient (s)
Calibrated linear storage time coefficient.
X — Inflow weighting factor
Weight in S=K[XI+(1−X)O].
dt — Hydrograph time step (s)
Must satisfy 2KX ≤ Δt ≤ 2K(1−X) for nonnegative routing coefficients.
O0 — Initial downstream outflow (m³/s)
Outflow at the first inflow sample, reflecting the assumed initial reach storage.

Interpreting the result

Linear storage approximation for one reach. No backwater, floodplain exchange, lateral inflow or hydraulic geometry-based parameter estimation. Educational model; this is not a code-compliant design check.

Reading the outputs

Peak and final discharge are m³/s; time of peak is a sampled offset from the first ordinate, and C0 is dimensionless.

Frequently asked questions

Why can a small time step be invalid?

If Δt<2KX the current-inflow coefficient becomes negative, violating this nonnegative-coefficient implementation.

Is the peak time exact?

It is the largest sampled outflow time; interpolation between samples is not performed.

Can one K and X describe all floods?

Not necessarily. Overbank storage and nonlinear wave behavior can change effective routing parameters.

How do I use the Muskingum flood reach routing calculator?

Enter Upstream inflow ordinates (m³/s), Reach storage travel coefficient (s), Inflow weighting factor, Hydrograph time step (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Muskingum flood reach routing?

Upstream inflow ordinates (m³/s) = [5, 10, 25, 40, 25, 10, 5, 5, 5]; Reach storage travel coefficient (s) = 900; Inflow weighting factor = 0.2; Hydrograph time step (s) = 600; Initial downstream outflow (m³/s) = 5. Peak downstream outflow: 30.233414 m³/s Final downstream outflow: 6.822481 m³/s Time of sampled peak: 2400 s Current-inflow routing coefficient: 0.117647 A hydrograph peaking at 40 m³/s is routed with K=900 s, X=0.2 and a 600 s interval, starting from 5 m³/s downstream flow.