CalcWorldHub
Free online calculator · no signup

Finite forward backward zero state filtering calculator

Apply a noncausal two-pass filter to an already recorded block while making the boundary convention explicit.

4,000 tools
Finite forward backward zero state filtering calculator — Uniform samples (signal units), Numerator coefficients b, Denominator coefficients a and calculation method
Finite forward backward zero state filtering calculator: inputs and calculation method.

How to use this calculator

Apply a noncausal two-pass filter to an already recorded block while making the boundary convention explicit.

  1. Enter Uniform samples (signal units), Numerator coefficients b, Denominator coefficients a. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Finite forward backward zero state filtering explained

A forward pass followed by a reverse pass removes phase in the interior but squares the filter magnitude response. With zero initial states and no endpoint padding, the finite record can show edge transients.

Middle forward backward value0.5969signal units
Middle forward backward value: 0.59689 signal units in the worked scenario.

A numerical walkthrough

Uniform samples (signal units) = [0, 0, 1, 2, 1, 0, 0, 0]; Numerator coefficients b = [0.2, 0.2]; Denominator coefficients a = [1, -0.6].

  • Middle forward backward value: 0.59689 signal units
  • Two-pass sample 0: 0.243283 signal units
  • Two-pass sample 1: 0.405472 signal units
  • Two-pass sample 2: 0.60912 signal units
  • Two-pass sample 3: 0.708534 signal units
  • Two-pass sample 4: 0.59689 signal units
  • Two-pass sample 5: 0.37775 signal units
  • Two-pass sample 6: 0.192676 signal units
  • Two-pass sample 7: 0.058982 signal units

A short positive pulse passes through the same low-pass recurrence in both directions; inspect the symmetric interior and affected edges.

The model behind the numbers

y=reverse(filter(reverse(filter(x)))) with zero initial state for each pass; away from boundaries Heff(e^iω)=|H(e^iω)|² for real coefficients.

The reverse pass cancels phase in the interior but squares the magnitude response. No extension, steady-state initialization or Gustafsson correction is used.

What to enter

x — Uniform samples (signal units)
Chronological real samples; use a comma-separated list in the same signal units. Use comma-separated values in the stated order.
b — Numerator coefficients b
Coefficients in ascending delay order b0,b1,… . Use comma-separated values in the stated order.
a — Denominator coefficients a
Coefficients a0,a1,… in ascending delay order; a0 cannot be zero. Use comma-separated values in the stated order.

Interpreting the result

Zero-state endpoints differ from common padded filtfilt defaults; this exact finite-record operation can distort both ends and cannot run live.

Reading the outputs

The complete two-pass record is returned in its original chronological order.

Frequently asked questions

Can this run on a live stream?

No. It requires future samples for the backward pass.

Is amplitude response unchanged?

No. The magnitude is squared, so attenuation increases.

Why differ from another filtfilt implementation?

Padding and initial-condition choices materially affect a short record.

How do I use the Finite forward backward zero state filtering calculator?

Enter Uniform samples (signal units), Numerator coefficients b, Denominator coefficients a. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Finite forward backward zero state filtering?

Uniform samples (signal units) = [0, 0, 1, 2, 1, 0, 0, 0]; Numerator coefficients b = [0.2, 0.2]; Denominator coefficients a = [1, -0.6]. Middle forward backward value: 0.59689 signal units Two-pass sample 0: 0.243283 signal units Two-pass sample 1: 0.405472 signal units Two-pass sample 2: 0.60912 signal units Two-pass sample 3: 0.708534 signal units Two-pass sample 4: 0.59689 signal units Two-pass sample 5: 0.37775 signal units Two-pass sample 6: 0.192676 signal units Two-pass sample 7: 0.058982 signal units A short positive pulse passes through the same low-pass recurrence in both directions; inspect the symmetric interior and affected edges.