CalcWorldHub
Free online calculator · no signup

Gaussian pulse duration from intensity autocorrelation calculator

Deconvolve a Gaussian background-free intensity autocorrelation width into an inferred pulse duration and inspect the measured baseline.

4,000 tools
Gaussian pulse duration from intensity autocorrelation calculator — Intensity autocorrelation FWHM (fs), Measured far delay baseline fraction and calculation method
Gaussian pulse duration from intensity autocorrelation calculator: inputs and calculation method.

How to use this calculator

Deconvolve a Gaussian background-free intensity autocorrelation width into an inferred pulse duration and inspect the measured baseline.

  1. Enter Intensity autocorrelation FWHM (fs), Measured far delay baseline fraction. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Gaussian pulse duration from intensity autocorrelation explained

Use Intensity autocorrelation FWHM (fs) with Measured far delay baseline fraction to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.

Gaussian pulse intensity FWHM106.066fs
Gaussian pulse intensity FWHM: 106.066017 fs in the worked scenario.

How the calculation works

A(τ)=∫I(t)I(t−τ)dt; a Gaussian intensity has τAC=√2 τpulse.

Width must be measured after subtracting a true constant baseline. The supplied baseline reports contrast only; it cannot repair an incorrect width measurement.

Set up the calculation

width — Intensity autocorrelation FWHM (fs)
Measured background-free intensity autocorrelation width.
background — Measured far delay baseline fraction
Baseline divided by central peak; diagnostic only.

Limits of this model

Intensity autocorrelation only, not interferometric autocorrelation. Gaussian shape is assumed; satellites, chirp and spectral phase cannot be reconstructed uniquely.

Check this example

Intensity autocorrelation FWHM (fs) = 150; Measured far delay baseline fraction = 0.

  • Gaussian pulse intensity FWHM: 106.066017 fs
  • Autocorrelation to pulse width factor: 1.414214
  • Peak to baseline contrast: No finite baseline

A 150 fs background-free Gaussian autocorrelation implies a pulse intensity FWHM of approximately 106.1 fs.

Reading the outputs

Inferred pulse width is fs. The deconvolution factor is dimensionless; baseline contrast is a ratio or an explicit zero-baseline label.

Frequently asked questions

Does an autocorrelation uniquely determine the pulse shape?

No. Many pulse profiles can share an autocorrelation.

Can I use the same factor for sech-squared pulses?

No. Their deconvolution factor differs.

Is an interferometric trace handled here?

No. Its fringes and baseline require a different analysis.

How do I use the Gaussian pulse duration from intensity autocorrelation calculator?

Enter Intensity autocorrelation FWHM (fs), Measured far delay baseline fraction. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Gaussian pulse duration from intensity autocorrelation?

Intensity autocorrelation FWHM (fs) = 150; Measured far delay baseline fraction = 0. Gaussian pulse intensity FWHM: 106.066017 fs Autocorrelation to pulse width factor: 1.414214 Peak to baseline contrast: No finite baseline A 150 fs background-free Gaussian autocorrelation implies a pulse intensity FWHM of approximately 106.1 fs.