How to use this calculator
Check two commonly used granular-filter size ratios against explicitly supplied criteria without labeling the filter as universally compliant.
- Enter Filter D15 (mm), Base-soil D15 (mm), Base-soil D85 (mm), Specified maximum retention ratio, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Granular filter retention and permeability ratio screening explained
The screen compares filter gradation with the base soil: D₁₅(filter)/D₈₅(base) is the retention ratio, while D₁₅(filter)/D₁₅(base) is the permeability ratio. Use sieve-derived particle sizes in one unit system. The entered limits produce screening margins only; passing these ratios does not replace filter compatibility checks, segregation controls, or project-specific design criteria.
Inputs, symbols, and units
D15f— Filter D15 (mm)- Filter particle diameter at 15% passing from its measured gradation.
D15b— Base-soil D15 (mm)- Base-soil diameter at 15% passing.
D85b— Base-soil D85 (mm)- Base-soil diameter at 85% passing; must be at least base D15.
Rmax— Specified maximum retention ratio- Project/method-specific upper limit for D15filter/D85base; no universal standard is selected.
Pmin— Specified minimum permeability ratio- Project/method-specific lower limit for D15filter/D15base.
Formula and method
Rret=D15filter/D85base; Rperm=D15filter/D15base. Margins are Rmax−Rret and Rperm−Pmin.
Retention favors smaller filter grains while permeability favors larger ones. These potentially competing checks use measured characteristic sizes and chosen method limits.
A worked scenario
Filter D15 (mm) = 0.6; Base-soil D15 (mm) = 0.08; Base-soil D85 (mm) = 0.3; Specified maximum retention ratio = 4; Specified minimum permeability ratio = 4.
- Retention ratio: 2
- Permeability ratio: 7.5
- Retention limit margin: 2
- Permeability limit margin: 3.5
A filter D15 of 0.6 mm over a base soil with D15=0.08 mm and D85=0.30 mm gives retention ratio 2 and permeability ratio 7.5.
Assumptions and edge cases
Basic size-ratio screening, not a complete filter design. Dispersive soils, gap grading, internal stability, segregation, clogging and the applicable granular-filter procedure need separate review. Educational model; this is not a code-compliant design check.
Reading the outputs
Ratios and margins are dimensionless. A negative margin fails the entered numerical criterion only, not a complete filter specification.
Frequently asked questions
Are the default limits mandatory standards?
No. They are editable example assumptions; select criteria suitable for the base-soil category and design method.
Does passing both margins ensure no piping?
No. Internal erosion, soil dispersivity and construction quality are not represented by two ratios.
Can D85 be smaller than D15?
Not on a valid cumulative grain-size curve; that input is rejected.
How do I use the Granular filter retention and permeability ratio screening calculator?
Enter Filter D15 (mm), Base-soil D15 (mm), Base-soil D85 (mm), Specified maximum retention ratio, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Granular filter retention and permeability ratio screening?
Filter D15 (mm) = 0.6; Base-soil D15 (mm) = 0.08; Base-soil D85 (mm) = 0.3; Specified maximum retention ratio = 4; Specified minimum permeability ratio = 4. Retention ratio: 2 Permeability ratio: 7.5 Retention limit margin: 2 Permeability limit margin: 3.5 A filter D15 of 0.6 mm over a base soil with D15=0.08 mm and D85=0.30 mm gives retention ratio 2 and permeability ratio 7.5.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume I.
Read our calculation methodology.