How to use this calculator
Extract D10, D30 and D60 from a cumulative sieve curve using semi-log interpolation and report two gradation descriptors.
- Enter Ascending particle diameters (mm), Corresponding percent passing (%). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Sieve grain size interpolation and gradation indices explained
A numerical walkthrough
Ascending particle diameters (mm) = [0.05, 0.1, 0.2, 0.5, 1, 2]; Corresponding percent passing (%) = [5, 15, 35, 65, 85, 100].
- Uniformity coefficient Cu: 6.069622
- Curvature coefficient Cc: 0.931994
- D10: 0.070711 mm
- D30: 0.168179 mm
- D60: 0.429187 mm
Diameters from 0.05 to 2 mm with passing percentages 5, 15, 35, 65, 85 and 100 bracket all three characteristic sizes. D30 lies between 0.1 and 0.2 mm.
The model behind the numbers
log Dp=log D1+(p−P1)(log D2−log D1)/(P2−P1); Cu=D60/D10; Cc=D30²/(D10D60).
Interpolation is linear in percent passing versus logarithm of diameter. The curve must actually cover all three target percentages; extrapolation is not allowed.
What to enter
d— Ascending particle diameters (mm)- Positive grain diameters from smallest to largest. Use comma-separated values in the stated order.
P— Corresponding percent passing (%)- Strictly increasing cumulative mass passing, paired with each diameter; must bracket 10, 30 and 60%. Use comma-separated values in the stated order.
Interpreting the result
Mass-based cumulative curve with monotonic distinct observations. These indices alone do not provide a complete soil classification or hydraulic conductivity. Educational model; this is not a code-compliant design check.
Reading the outputs
Cu and Cc are dimensionless. D10, D30 and D60 are particle diameters in mm, not percentages.
Assumptions and limits
Use particle diameters in ascending order with nondecreasing percent passing. D10, D30 and D60 must be bracketed by supplied measurements because interpolation is logarithmic only between adjacent points; the resulting indices do not replace a soil-classification standard.
Frequently asked questions
Why not interpolate diameter directly?
Sieve curves conventionally use a logarithmic diameter axis; arithmetic interpolation gives a different characteristic size.
What if the curve does not reach 10% passing?
D10 is not established by the data; add finer-size measurements rather than extrapolating.
Does high Cu alone mean well graded?
No. Curvature, fines and the applicable classification criteria also matter.
How do I use the Sieve grain size interpolation and gradation indices calculator?
Enter Ascending particle diameters (mm), Corresponding percent passing (%). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Sieve grain size interpolation and gradation indices?
Ascending particle diameters (mm) = [0.05, 0.1, 0.2, 0.5, 1, 2]; Corresponding percent passing (%) = [5, 15, 35, 65, 85, 100]. Uniformity coefficient Cu: 6.069622 Curvature coefficient Cc: 0.931994 D10: 0.070711 mm D30: 0.168179 mm D60: 0.429187 mm Diameters from 0.05 to 2 mm with passing percentages 5, 15, 35, 65, 85 and 100 bracket all three characteristic sizes. D30 lies between 0.1 and 0.2 mm.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume I.
Read our calculation methodology.