How to use this calculator
Calculate the gross Wobbe index from a fuel gas higher heating value and relative density.
- Enter Gross higher heating value (MJ/m³), Relative density to air. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The gross Wobbe index compares the volume-basis higher heating value of a combustible gas with the square root of its relative density to air. Both inputs must use the same reference conditions for a valid comparison.
Inputs and units
higherHeatingValueMjM3— Gross higher heating value (MJ/m³)- Volume-basis gross calorific value at the selected reference conditions.
relativeDensity— Relative density to air- Gas density divided by air density at the same reference conditions.
Formula
W_gross = HHV/sqrt(d_relative).
Method
Enter higher heating value in megajoules per cubic metre and relative density to air at matching reference conditions. The result has the same energy-per-volume units as the heating value.
Worked example
For a gross heating value of 39.8 MJ/m³ and relative density 0.60, the gross Wobbe index is 51.3816 MJ/m³.
Assumptions and limits
The index is a gas-interchangeability indicator, not a complete burner or appliance safety assessment. Confirm heating-value basis, reference temperature and pressure, gas composition, and applicable equipment specifications.
Frequently asked questions
What does the Wobbe index compare?
It scales volume-basis heating value by the square root of gas relative density to air.
Why must reference conditions match?
Density and volumetric heating value vary with reference temperature and pressure.
Does a similar Wobbe index guarantee safe interchangeability?
No. Other combustion, emissions, pressure, and appliance constraints still apply.
How do I use the Gross Wobbe Index Calculator?
Enter Gross higher heating value (MJ/m³), Relative density to air. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Gross Wobbe Index?
For a gross heating value of 39.8 MJ/m³ and relative density 0.60, the gross Wobbe index is 51.3816 MJ/m³.
Reference: ISO 6976 natural-gas calorific value, relative density, and Wobbe index standard. See our calculation methodology.