Heat integration pinch cascade calculator
Build a shifted-temperature heat cascade to estimate minimum external heating and cooling for sensible process streams.
How to use this calculator
Build a shifted-temperature heat cascade to estimate minimum external heating and cooling for sensible process streams.
- Enter Stream inlet temperatures (°C), Matching outlet temperatures (°C), Stream heat-capacity rates (kW/K), Minimum hot-cold approach (K). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How the Heat integration pinch cascade calculator works
Build a shifted-temperature heat cascade to estimate minimum external heating and cooling for sensible process streams.
Inputs and units
- Stream inlet temperatures (°C): Comma-separated inlet temperatures in °C; keep the same stream order in every list.
- Matching outlet temperatures (°C): Matching target outlet temperatures; inlet above outlet denotes a hot stream.
- Stream heat-capacity rates (kW/K): Matching positive heat-capacity rates in kW/K, meaning mass flow times specific heat.
- Minimum hot-cold approach (K): Nonnegative minimum allowed hot-to-cold temperature approach, in kelvins.
Formula and method
Shift hot temperatures down by ΔTmin/2 and cold temperatures up by ΔTmin/2; cascade ΣCPhot−ΣCPcold over each interval.
Worked example
Hot stream 150→60°C at 2 kW/K and cold stream 50→160°C at 1.5 kW/K, with ΔTmin=20 K, give shifted levels 170,140,60,50°C. Interval duties are −45,+40,+20 kW; adding 45 kW hot utility leaves 60 kW cold utility.
Interpreting the result
The most negative uncorrected cascade sets the minimum hot utility. The final corrected balance is minimum cold utility; zero balances identify shifted pinch levels.
Assumptions and limits
Heat-capacity rates are constant, streams exchange sensible heat, and the chosen approach applies across the network. Phase changes, exchanger areas, pressure constraints, and network topology are not designed here.
Sources and method
- Explains shifted temperatures, interval balances, and the heat-cascade utility targeting method. Northwestern Chemical Process Design: pinch analysis
Frequently asked questions
Are the pinch temperatures actual stream temperatures?
The reported levels are shifted. Recover actual hot and cold pinch temperatures by adding and subtracting ΔTmin/2 respectively.
Does this size the heat exchangers?
No. It provides energy targets; areas, matches, feasibility, and economics require a network design.
How do I use the Heat integration pinch cascade calculator?
Enter Stream inlet temperatures (°C), Matching outlet temperatures (°C), Stream heat-capacity rates (kW/K), Minimum hot-cold approach (K). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Heat integration pinch cascade?
Hot stream 150→60°C at 2 kW/K and cold stream 50→160°C at 1.5 kW/K, with ΔTmin=20 K, give shifted levels 170,140,60,50°C. Interval duties are −45,+40,+20 kW; adding 45 kW hot utility leaves 60 kW cold utility.
What does the Heat integration pinch cascade calculator calculate?
Build a shifted-temperature heat cascade to estimate minimum external heating and cooling for sensible process streams.
See the calculation methodology.