How to use this calculator
Integrate infiltration and runoff-producing rainfall excess during a constant-intensity storm while respecting rainfall supply.
- Enter Initial infiltration capacity (mm/hour), Asymptotic capacity (mm/hour), Capacity decay constant (1/hour), Constant storm duration (hours), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Horton constant storm rainfall excess explained
Horton capacity decays exponentially from the initial rate toward the asymptotic rate. Actual infiltration integrates the smaller of that capacity and rainfall supply; excess is the rainfall depth left after infiltration.
Inputs, symbols, and units
f0— Initial infiltration capacity (mm/hour)- Initial capacity at the storm start under the stated Horton decay model.
fc— Asymptotic capacity (mm/hour)- Long-time lower capacity, no greater than f0.
k— Capacity decay constant (1/hour)- Exponential capacity decay rate during the wet period.
t— Constant storm duration (hours)- Duration of the uninterrupted rainfall event.
r— Constant rainfall intensity (mm/hour)- Available rainfall supply; actual infiltration cannot exceed it.
Formula and method
f(t)=fc+(f0−fc)e^(−kt); infiltration depth=∫min[r,f(t)]dt; excess=rt−Finfil.
If rainfall starts below initial capacity but above the limiting capacity, the integration switches at the analytical crossing time. It does not assume the entire capacity is used before ponding.
A worked scenario
Initial infiltration capacity (mm/hour) = 35; Asymptotic capacity (mm/hour) = 8; Capacity decay constant (1/hour) = 1.2; Constant storm duration (hours) = 2; Constant rainfall intensity (mm/hour) = 20.
- Rainfall excess depth: 7.931852 mm
- Actual infiltrated depth: 32.068148 mm
- End actual infiltration rate: 10.449385 mm/hour
A two-hour storm at 20 mm/h acts on a surface with initial capacity 35 mm/h, final capacity 8 mm/h and decay constant 1.2 h⁻¹.
Assumptions and edge cases
Empirical monotonic Horton capacity decay through one constant storm; no drying recovery, depression storage or variable rainfall sequence. Educational model; this is not a code-compliant design check.
Reading the outputs
Excess and actual infiltration are mm; the final actual infiltration rate is mm/h and is capped by rainfall intensity.
Frequently asked questions
Can runoff occur before rainfall exceeds capacity?
Not in this model; all supplied rainfall infiltrates until the capacity falls below the rainfall intensity.
Why not use capacity directly as infiltration?
Capacity is an upper bound; there is no water to infiltrate above the available rainfall supply.
Does this include surface storage?
No. Excess is runoff-producing water before any separate surface detention routing.
How do I use the Horton constant storm rainfall excess calculator?
Enter Initial infiltration capacity (mm/hour), Asymptotic capacity (mm/hour), Capacity decay constant (1/hour), Constant storm duration (hours), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Horton constant storm rainfall excess?
Initial infiltration capacity (mm/hour) = 35; Asymptotic capacity (mm/hour) = 8; Capacity decay constant (1/hour) = 1.2; Constant storm duration (hours) = 2; Constant rainfall intensity (mm/hour) = 20. Rainfall excess depth: 7.931852 mm Actual infiltrated depth: 32.068148 mm End actual infiltration rate: 10.449385 mm/hour A two-hour storm at 20 mm/h acts on a surface with initial capacity 35 mm/h, final capacity 8 mm/h and decay constant 1.2 h⁻¹.
Read our calculation methodology.