CalcWorldHub
Free online calculator · no signup

Internally heated symmetric slab temperature profile calculator

Find the hot center of a power-generating plate whose two faces lose heat to the same fluid.

4,000 tools
Internally heated symmetric slab temperature profile calculator — Slab half-thickness (m), Solid conductivity (W/m/K), Uniform heat generation (W/m³) and calculation method
Internally heated symmetric slab temperature profile calculator: inputs and calculation method.

How to use this calculator

Find the hot center of a power-generating plate whose two faces lose heat to the same fluid.

  1. Enter Slab half-thickness (m), Solid conductivity (W/m/K), Uniform heat generation (W/m³), Convection coefficient on each face (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Internally heated symmetric slab temperature profile explained

Evaluate the steady one-dimensional temperature profile of a uniformly heated symmetric slab.

Maximum center temperature46.3333°C
Maximum center temperature: 46.333333 °C in the worked scenario.

How the calculation works

T(x)=Ta+qvL/h+qv(L²−x²)/(2k), for −L≤x≤L with equal convection on both faces.

Integrate kT″+qv=0 with zero centerline gradient and equal face convection. Half the generated heat leaves through each face.

Set up the calculation

L — Slab half-thickness (m)
Distance L from the center plane to either exposed face; the full slab thickness is 2L.
k — Solid conductivity (W/m/K)
Thermal conductivity k assumed constant through the slab.
qv — Uniform heat generation (W/m³)
Volumetric heat-generation rate q‴ assumed uniform and steady throughout the solid.
hc — Convection coefficient on each face (W/m²/K)
Film coefficient h for either face; the model uses the same value on both sides.
Ta — Ambient fluid temperature (°C)
Common ambient temperature of the fluid on both slab faces.
x — Distance from center plane (m)
Location x measured from the symmetry plane; require |x|≤L.

Limits of this model

Steady uniform volumetric generation, constant conductivity, equal ambient and convection on both faces. No radiation or temperature-dependent resistivity.

Check this example

Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 15; Uniform heat generation (W/m³) = 100000; Convection coefficient on each face (W/m²/K) = 100; Ambient fluid temperature (°C) = 25; Distance from center plane (m) = 0.01.

  • Maximum center temperature: 46.333333 °C
  • Surface temperature: 45 °C
  • Temperature at position: 46 °C
  • Heat generated per planform area: 4000 W/m²

A 0.04 m full-thickness symmetric slab generates 100,000 W/m³ with k=15 W/m/K and h=100 W/m²/K into 25 °C fluid. Each face releases 2,000 W/m², while the center reaches 46.3333 °C and the point 0.01 m from center reaches 46 °C.

Reading the outputs

Reports center maximum, face temperature, selected interior temperature and total two-face generated heat per plate plan area.

Frequently asked questions

Is L the full thickness?

No. Full thickness is 2L because the centerline is a symmetry plane.

Does total generated flux equal the flux from one face?

No. Each face carries qv L; the reported total per planform area is 2qv L.

Can I use this for one insulated and one cooled face?

Only by redefining the symmetry length appropriately for an equivalent one-sided slab; physical dimensions must follow the boundary conditions.

How do I use the Internally heated symmetric slab temperature profile calculator?

Enter Slab half-thickness (m), Solid conductivity (W/m/K), Uniform heat generation (W/m³), Convection coefficient on each face (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Internally heated symmetric slab temperature profile?

Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 15; Uniform heat generation (W/m³) = 100000; Convection coefficient on each face (W/m²/K) = 100; Ambient fluid temperature (°C) = 25; Distance from center plane (m) = 0.01. Maximum center temperature: 46.333333 °C Surface temperature: 45 °C Temperature at position: 46 °C Heat generated per planform area: 4000 W/m² A 0.04 m full-thickness symmetric slab generates 100,000 W/m³ with k=15 W/m/K and h=100 W/m²/K into 25 °C fluid. Each face releases 2,000 W/m², while the center reaches 46.3333 °C and the point 0.01 m from center reaches 46 °C.