How to use this calculator
Find the hot center of a power-generating plate whose two faces lose heat to the same fluid.
- Enter Slab half-thickness (m), Solid conductivity (W/m/K), Uniform heat generation (W/m³), Convection coefficient on each face (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Internally heated symmetric slab temperature profile explained
Evaluate the steady one-dimensional temperature profile of a uniformly heated symmetric slab.
How the calculation works
T(x)=Ta+qvL/h+qv(L²−x²)/(2k), for −L≤x≤L with equal convection on both faces.
Integrate kT″+qv=0 with zero centerline gradient and equal face convection. Half the generated heat leaves through each face.
Set up the calculation
L— Slab half-thickness (m)- Distance L from the center plane to either exposed face; the full slab thickness is 2L.
k— Solid conductivity (W/m/K)- Thermal conductivity k assumed constant through the slab.
qv— Uniform heat generation (W/m³)- Volumetric heat-generation rate q‴ assumed uniform and steady throughout the solid.
hc— Convection coefficient on each face (W/m²/K)- Film coefficient h for either face; the model uses the same value on both sides.
Ta— Ambient fluid temperature (°C)- Common ambient temperature of the fluid on both slab faces.
x— Distance from center plane (m)- Location x measured from the symmetry plane; require |x|≤L.
Limits of this model
Steady uniform volumetric generation, constant conductivity, equal ambient and convection on both faces. No radiation or temperature-dependent resistivity.
Check this example
Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 15; Uniform heat generation (W/m³) = 100000; Convection coefficient on each face (W/m²/K) = 100; Ambient fluid temperature (°C) = 25; Distance from center plane (m) = 0.01.
- Maximum center temperature: 46.333333 °C
- Surface temperature: 45 °C
- Temperature at position: 46 °C
- Heat generated per planform area: 4000 W/m²
A 0.04 m full-thickness symmetric slab generates 100,000 W/m³ with k=15 W/m/K and h=100 W/m²/K into 25 °C fluid. Each face releases 2,000 W/m², while the center reaches 46.3333 °C and the point 0.01 m from center reaches 46 °C.
Reading the outputs
Reports center maximum, face temperature, selected interior temperature and total two-face generated heat per plate plan area.
Frequently asked questions
Is L the full thickness?
No. Full thickness is 2L because the centerline is a symmetry plane.
Does total generated flux equal the flux from one face?
No. Each face carries qv L; the reported total per planform area is 2qv L.
Can I use this for one insulated and one cooled face?
Only by redefining the symmetry length appropriately for an equivalent one-sided slab; physical dimensions must follow the boundary conditions.
How do I use the Internally heated symmetric slab temperature profile calculator?
Enter Slab half-thickness (m), Solid conductivity (W/m/K), Uniform heat generation (W/m³), Convection coefficient on each face (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Internally heated symmetric slab temperature profile?
Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 15; Uniform heat generation (W/m³) = 100000; Convection coefficient on each face (W/m²/K) = 100; Ambient fluid temperature (°C) = 25; Distance from center plane (m) = 0.01. Maximum center temperature: 46.333333 °C Surface temperature: 45 °C Temperature at position: 46 °C Heat generated per planform area: 4000 W/m² A 0.04 m full-thickness symmetric slab generates 100,000 W/m³ with k=15 W/m/K and h=100 W/m²/K into 25 °C fluid. Each face releases 2,000 W/m², while the center reaches 46.3333 °C and the point 0.01 m from center reaches 46 °C.
Read our calculation methodology.