How to use this calculator
Resolve through-thickness temperature gradients during symmetric cooling or heating of a finite slab when lumped temperature is insufficient.
- Enter Slab half-thickness (m), Solid conductivity (W/m/K), Thermal diffusivity (m²/s), Convection coefficient on both faces (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Finite slab transient convection eigenfunction explained
How the calculation works
θ/θi=ΣAn exp(−ζn²Fo)cos(ζnx/L), ζn tan ζn=Bi; An=4sinζn/(2ζn+sin2ζn).
Find the convective eigenvalues and sum sixty decaying modes. Half-thickness defines Biot and Fourier numbers; the spatial coordinate is measured from the symmetry center.
Set up the calculation
L— Slab half-thickness (m)- Half-thickness from the slab midplane to either exposed face; both Biot and Fourier numbers use this length.
k— Solid conductivity (W/m/K)- Thermal conductivity of the solid in W/(m·K). Together with h, it sets the Biot number.
alpha— Thermal diffusivity (m²/s)- Thermal diffusivity in m²/s. It sets how quickly the transient penetrates the slab.
hc— Convection coefficient on both faces (W/m²/K)- Convective heat-transfer coefficient at each of the two slab faces.
Ti— Uniform initial temperature (°C)- Elapsed seconds since the boundary temperature changed.
Ta— Fluid step temperature (°C)- Fluid temperature imposed at both faces after the step; use an absolute temperature scale consistently if interpreting energy properties.
t— Elapsed time (s)- Elapsed time (s). Enter the value for this state; the units shown are used without an unstated conversion.
x— Distance from slab center (m)- Distance from the slab midplane, from 0 at the center to L at a face.
Limits of this model
Uniform initial temperature, equal face convection, constant properties and a sudden fixed fluid temperature. Fo≥0.02 guards early-time series convergence.
Check this example
Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 1.5; Thermal diffusivity (m²/s) = 7.00000000e-07; Convection coefficient on both faces (W/m²/K) = 50; Uniform initial temperature (°C) = 100; Fluid step temperature (°C) = 20; Elapsed time (s) = 600; Distance from slab center (m) = 0.01.
- Temperature at depth: 66.002013 °C
- Center temperature: 69.302874 °C
- Biot number: 0.666667
- Fourier number: 1.05
A slab of half-thickness 0.02 m initially at 100 °C cools for 600 s into 20 °C fluid with h=50 W/m²/K. Biot number is 0.666667, so internal gradients matter: the center is 69.3029 °C while the point halfway to the face is 66.0020 °C.
Reading the outputs
Reports local and center temperatures, Biot number hL/k and Fourier number alpha t/L².
Frequently asked questions
Why does this accept Biot numbers above 0.1?
The spatial eigenfunctions explicitly resolve internal gradients rather than assuming a uniform body temperature.
Is x measured from the exposed face?
No. x=0 is the center and x=L is either face.
Why reject very short times?
A finite mode sum converges slowly immediately after the boundary step; use an early-time semi-infinite model where appropriate.
How do I use the Finite slab transient convection eigenfunction calculator?
Enter Slab half-thickness (m), Solid conductivity (W/m/K), Thermal diffusivity (m²/s), Convection coefficient on both faces (W/m²/K), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Finite slab transient convection eigenfunction?
Slab half-thickness (m) = 0.02; Solid conductivity (W/m/K) = 1.5; Thermal diffusivity (m²/s) = 7.00000000e-07; Convection coefficient on both faces (W/m²/K) = 50; Uniform initial temperature (°C) = 100; Fluid step temperature (°C) = 20; Elapsed time (s) = 600; Distance from slab center (m) = 0.01. Temperature at depth: 66.002013 °C Center temperature: 69.302874 °C Biot number: 0.666667 Fourier number: 1.05 A slab of half-thickness 0.02 m initially at 100 °C cools for 600 s into 20 °C fluid with h=50 W/m²/K. Biot number is 0.666667, so internal gradients matter: the center is 69.3029 °C while the point halfway to the face is 66.0020 °C.
Background or definition reference: IIT NPTEL Heat Transfer course.
Read our calculation methodology.