How to use this calculator
Calculate equal-size Laney P′ chart limits with a moving-range correction for overdispersion.
- Enter Defective units in each subgroup, in time order, Units in every subgroup, n. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
A Laney P′ chart adjusts the conventional p-chart standard deviation by measuring variation in consecutive standardized subgroup proportions. This calculator uses equal-sized subgroups and estimates the center line from the entered baseline subgroups.
Inputs and units
defectiveCounts— Defective units in each subgroup, in time order- Enter one nonnegative whole-number defective count per subgroup.
subgroupSize— Units in every subgroup, n- All entered subgroups must have this same sample size.
Formula
p̄ = Σdᵢ/(mn); zᵢ = (dᵢ/n − p̄)/√[p̄(1−p̄)/n]; σz = MR̄z/1.128; limits = p̄ ± 3σz√[p̄(1−p̄)/n].
Method
Find the pooled fraction defective, standardize each subgroup proportion, calculate the average moving range of adjacent z-scores, and divide it by 1.128. Apply three adjusted standard deviations to the center line and clip limits to the valid proportion range from 0 to 1.
Worked example
For four subgroups with 200 units each and defective counts [10, 12, 8, 11], p̄ = 0.05125, σz ≈ 0.8529, LCL ≈ 0.01136, and UCL ≈ 0.09114.
Assumptions and limits
Use at least three chronologically ordered, equal-sized baseline subgroups. The calculation uses a three-sigma limit and does not test process stability or apply supplementary run rules. A Sigma-Z below 1 narrows limits; a value above 1 widens them.
Frequently asked questions
Why does a Laney P′ chart differ from a P chart?
It adjusts the p-chart limits using variation in adjacent standardized subgroup proportions.
Can subgroup sizes vary?
This calculator requires one common subgroup size so the resulting limits are directly comparable.
Does a limit show that the process is stable?
No. Control limits support a chart; stability still requires reviewing the plotted sequence and an appropriate set of control-chart rules.
How do I use the Laney P′ Proportion Control Limits Calculator?
Enter Defective units in each subgroup, in time order, Units in every subgroup, n. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Laney P′ Proportion Control Limits?
For four subgroups with 200 units each and defective counts [10, 12, 8, 11], p̄ = 0.05125, σz ≈ 0.8529, LCL ≈ 0.01136, and UCL ≈ 0.09114.
Reference: Minitab Laney P′ chart methods and formulas. See our calculation methodology.