How to use this calculator
Estimate electrical output from hydropower flow, net head, and turbine-generator efficiency.
- Enter Water flow (L/s), Net head at turbine (m), Turbine-generator efficiency (%), Operating hours per day. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Hydropower converts the gravitational energy of flowing water into electrical output. This estimate multiplies net head, water flow, water density, gravity, and an entered overall turbine-generator efficiency. Net head should account for penstock and intake losses before reaching the turbine.
Inputs and units
flowLps— Water flow (L/s)- Enter flow available to the turbine, not total river flow unless all of it can be used.
netHeadM— Net head at turbine (m)- Enter gross elevation head minus intake and penstock losses.
efficiencyPct— Turbine-generator efficiency (%)- Enter combined turbine and generator efficiency from 0 to 100%.
hoursPerDay— Operating hours per day- Use 0 to 24 hours for a daily energy estimate.
Formula
P_electric = ρ g Q H_net η; for water and Q in L/s, P_kW ≈ 0.00980665 Q H_net η_fraction.
Method
Convert flow from litres per second to cubic metres per second, multiply by water density 1,000 kg/m³, gravity 9.80665 m/s², net head in metres, and efficiency as a fraction. Divide watts by 1,000 for kW, then multiply by operating hours for daily kWh.
Worked example
For 5 L/s at 12 m net head, 70% overall efficiency, and 8 operating hours per day, estimated output is 0.4119 kW and daily energy is 3.295 kWh.
Assumptions and limits
This idealized estimate assumes water density near 1,000 kg/m³ and uses net head at the turbine. It omits seasonal flow, environmental releases, generator auxiliaries, grid limits, downtime, and detailed turbine performance.
Frequently asked questions
What is net head?
It is the usable head at the turbine after subtracting hydraulic losses from the gross elevation difference.
Should I enter turbine or combined efficiency?
For electrical output, use combined turbine-generator efficiency, or overall efficiency if intake and other conversion losses are also included.
Does this predict annual generation?
No. It uses one flow and head condition; annual energy needs a time series or flow-duration distribution.
How do I use the Microhydropower Output Calculator?
Enter Water flow (L/s), Net head at turbine (m), Turbine-generator efficiency (%), Operating hours per day. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Microhydropower Output?
For 5 L/s at 12 m net head, 70% overall efficiency, and 8 operating hours per day, estimated output is 0.4119 kW and daily energy is 3.295 kWh.
Reference: U.S. Department of Energy hydroelectric course equation for output from flow, head, and turbine-generator efficiency. See our calculation methodology.