CalcWorldHub
Free online calculator · no signup

Orifice Discharge Coefficient from Measured Flow Calculator

Estimate an orifice discharge coefficient from measured flow, opening diameter, and differential head.

4,000 tools
Orifice Discharge Coefficient from Measured Flow Calculator — Measured discharge (L/s), Circular opening diameter (mm), Differential head across the opening (m) and calculation method
Orifice Discharge Coefficient from Measured Flow Calculator: inputs and calculation method.

How to use this calculator

Estimate an orifice discharge coefficient from measured flow, opening diameter, and differential head.

  1. Enter Measured discharge (L/s), Circular opening diameter (mm), Differential head across the opening (m). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Water engineering calculation

How this calculation works

Enter measured discharge, circular opening diameter, and head difference across the opening. The coefficient compares measured flow with the ideal velocity-head discharge for the entered geometry.

Inputs and units

measuredFlowLs — Measured discharge (L/s)
Measured volumetric flow rate through the tested opening.
diameterMm — Circular opening diameter (mm)
Clear diameter of the circular opening.
headDifferenceM — Differential head across the opening (m)
Upstream minus downstream piezometric head for the measured configuration.

Formula

Displayed formula

Cd = Qmeasured ÷ [A√(2gΔH)], where A = πd²/4 and g = 9.80665 m/s².

Method

Convert measured flow from litres per second to cubic metres per second, and diameter from millimetres to metres. Compute the ideal flow from the opening area and differential head, then divide measured flow by that ideal flow.

Worked example

A 50 mm opening under a 0.50 m differential head has ideal discharge about 6.15 L/s; a measured 3.70 L/s gives Cd ≈ 0.602.

Assumptions and limits

The discharge coefficient depends on opening geometry and where head is measured; it is normally determined experimentally for the installed configuration. This calculator is not a general orifice-sizing standard and does not account for approach velocity or all submerged-flow corrections.

Frequently asked questions

What is the discharge coefficient?

It is the measured flow divided by the ideal flow predicted from opening area and differential head.

Is Cd constant for every orifice?

No. Geometry and the measurement locations affect the coefficient; determine it for the specific configuration.

Does this correct for approach velocity?

No. The simple relation shown assumes approach-velocity effects can be neglected or are handled separately.

How do I use the Orifice Discharge Coefficient from Measured Flow Calculator?

Enter Measured discharge (L/s), Circular opening diameter (mm), Differential head across the opening (m). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Orifice Discharge Coefficient from Measured Flow?

A 50 mm opening under a 0.50 m differential head has ideal discharge about 6.15 L/s; a measured 3.70 L/s gives Cd ≈ 0.602.