How to use this calculator
Compare characteristic advection speed with diffusion using the Péclet number for heat or mass transport.
- Enter Characteristic speed U (m/s), Characteristic length L (m), Thermal or mass diffusivity D (m²/s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The Péclet number compares transport carried by a moving fluid with transport spread by diffusion. It is calculated from the characteristic speed, characteristic length, and the matching diffusivity: use thermal diffusivity for heat or mass diffusivity for a dissolved species. The value is dimensionless; a larger value means advection is stronger relative to diffusion for the chosen scale.
Inputs and units
velocity— Characteristic speed U (m/s)- Use a nonnegative characteristic flow speed.
length— Characteristic length L (m)- Use the length scale relevant to the transport problem.
diffusivity— Thermal or mass diffusivity D (m²/s)- Enter thermal diffusivity for heat or mass diffusivity for species transport.
Formula
Pe = U L / D, where D is the diffusivity for the transported quantity.
Method
Multiply speed U by characteristic length L, then divide by the thermal or mass diffusivity D. All inputs use SI units.
Worked example
For U = 0.20 m/s, L = 0.050 m, and D = 2.0 × 10⁻⁵ m²/s, Pe = 500.00. Advection is 500 times the diffusion scale for these inputs.
Assumptions and limits
This is a scale-dependent comparison. The useful threshold and length scale depend on geometry, boundary conditions, and the transport model.
Frequently asked questions
What does a large Péclet number mean?
It means advective transport is large relative to diffusion over the selected speed and length scales; the model-specific interpretation depends on the flow and boundary conditions.
Should I enter thermal or mass diffusivity?
Use thermal diffusivity when tracking temperature and mass diffusivity when tracking a chemical species or tracer.
Is the Péclet number unitless?
Yes. The units of speed times length cancel the units of diffusivity, leaving a dimensionless ratio.
How do I use the Péclet Number Calculator?
Enter Characteristic speed U (m/s), Characteristic length L (m), Thermal or mass diffusivity D (m²/s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Péclet Number?
For U = 0.20 m/s, L = 0.050 m, and D = 2.0 × 10⁻⁵ m²/s, Pe = 500.00. Advection is 500 times the diffusion scale for these inputs.
Reference: MIT transport note on the Péclet number and advection–diffusion scaling. See our calculation methodology.