CalcWorldHub
Free online calculator · no signup

Stokes–Einstein Diffusion Coefficient Calculator

Estimate dilute-solution translational diffusivity from temperature, solvent viscosity, and hydrodynamic radius.

4,000 tools
Stokes–Einstein Diffusion Coefficient Calculator — Temperature (°C), Dynamic viscosity (mPa·s), Hydrodynamic radius (nm) and calculation method
Stokes–Einstein Diffusion Coefficient Calculator: inputs and calculation method.

How to use this calculator

Estimate dilute-solution translational diffusivity from temperature, solvent viscosity, and hydrodynamic radius.

  1. Enter Temperature (°C), Dynamic viscosity (mPa·s), Hydrodynamic radius (nm). Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Chemistry calculation

How this calculation works

The Stokes–Einstein relation connects translational diffusion to absolute temperature, continuum viscosity, and the hydrodynamic radius of an isolated dissolved or dispersed entity.

Inputs and units

temperatureC — Temperature (°C)
Solution temperature; must be above absolute zero.
viscosityMpas — Dynamic viscosity (mPa·s)
Solvent or dispersion-medium viscosity at the specified temperature.
radiusNm — Hydrodynamic radius (nm)
Effective radius of the diffusing entity, including coupled solvent where appropriate.

Formula

Displayed formula

D = k_B T ÷ (6π η r_H).

Method

Enter temperature in Celsius, dynamic viscosity in mPa·s, and hydrodynamic radius in nanometers. The temperature is converted to kelvins and the outputs are reported in μm²/s and m²/s.

Worked example

At 25 °C with viscosity 0.890 mPa·s and hydrodynamic radius 1.00 nm, D = 245.37 µm²/s (2.4537 ×10⁻¹⁰ m²/s).

Assumptions and limits

Assumes a spherical entity in a dilute Newtonian continuum with no wall, crowding, association, or non-Stokes hydrodynamic effects. Use a measured or defensible hydrodynamic radius and viscosity at the entered temperature; the simple relation may not describe concentrated or strongly structured solutions.

Frequently asked questions

What is hydrodynamic radius?

It is the effective size of a moving entity together with solvent that moves with it, as represented by the diffusion model.

Why use absolute temperature?

Thermal motion depends on kelvins, so Celsius is converted by adding 273.15.

Does a larger particle diffuse faster?

No. In this relation, diffusion decreases as hydrodynamic radius or viscosity increases.

How do I use the Stokes–Einstein Diffusion Coefficient Calculator?

Enter Temperature (°C), Dynamic viscosity (mPa·s), Hydrodynamic radius (nm). Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Stokes–Einstein Diffusion Coefficient?

At 25 °C with viscosity 0.890 mPa·s and hydrodynamic radius 1.00 nm, D = 245.37 µm²/s (2.4537 ×10⁻¹⁰ m²/s).