Steady axial advection diffusion temperature boundary problem calculator

Resolve the competition between axial transport and conduction when temperatures are prescribed at both ends of a one-dimensional domain.

4,000 tools
Steady axial advection diffusion temperature boundary problem calculator — Upstream boundary temperature (°C), Downstream boundary temperature (°C), Domain length (m) and calculation method
Steady axial advection diffusion temperature boundary problem calculator: inputs and calculation method.

How to use this calculator

Resolve the competition between axial transport and conduction when temperatures are prescribed at both ends of a one-dimensional domain.

  1. Enter Upstream boundary temperature (°C), Downstream boundary temperature (°C), Domain length (m), Uniform axial transport speed (m/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Steady axial advection diffusion temperature boundary problem explained

Steady local temperature50.2033°C
Steady local temperature: 50.203254 °C in the worked scenario.

How the calculation works

αT″−vT′=0; T=T₁+(T₂−T₁)(e^(Pe x/L)−1)/(e^Pe−1), Pe=vL/α.

Solve the steady convection–diffusion boundary problem exactly and differentiate it to report conductive flux. Negative speed reverses transport without swapping boundary definitions.

Set up the calculation

T1 — Upstream boundary temperature (°C)
Upstream boundary temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T2 — Downstream boundary temperature (°C)
Downstream boundary temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
L — Domain length (m)
Domain length (m). Enter the value for this state; the units shown are used without an unstated conversion.
v — Uniform axial transport speed (m/s)
Uniform axial transport speed (m/s). Enter the value for this state; the units shown are used without an unstated conversion.
alpha — Thermal diffusivity (m²/s)
Thermal diffusivity (m²/s). Enter the value for this state; the units shown are used without an unstated conversion.
k — Effective axial conductivity (W/m/K)
Effective axial conductivity (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
x — Evaluation coordinate from boundary 1 (m)
Evaluation coordinate from boundary 1 (m). Enter the value for this state; the units shown are used without an unstated conversion.

Limits of this model

Constant speed, diffusivity and conductivity, no lateral loss or internal source. A fixed downstream temperature may generate a narrow boundary layer at high Peclet number.

Check this example

Upstream boundary temperature (°C) = 20; Downstream boundary temperature (°C) = 100; Domain length (m) = 0.1; Uniform axial transport speed (m/s) = 0.0001; Thermal diffusivity (m²/s) = 0.00001; Effective axial conductivity (W/m/K) = 0.6; Evaluation coordinate from boundary 1 (m) = 0.05.

  • Steady local temperature: 50.203254 °C
  • Signed axial conductive heat flux: -460.56834 W/m²
  • Signed length Peclet number: 1

A 0.1 m domain has 20 and 100 °C end temperatures, speed 0.0001 m/s and diffusivity 1e−5 m²/s. At its midpoint, Peclet number 1 gives 50.2033 °C rather than the 60 °C conduction-only midpoint; conductive flux there is −460.568 W/m².

Reading the outputs

Temperature is °C, conductive flux is W/m² positive toward increasing x, and Peclet number is signed.

Frequently asked questions

Why is the profile not linear?

Advection carries thermal energy downstream while conduction acts in both directions.

Does the reported flux include advected enthalpy?

No. It is only the Fourier conductive component.

What happens at zero speed?

The exponential expression is replaced by its linear conduction limit.

How do I use the Steady axial advection diffusion temperature boundary problem calculator?

Enter Upstream boundary temperature (°C), Downstream boundary temperature (°C), Domain length (m), Uniform axial transport speed (m/s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Steady axial advection diffusion temperature boundary problem?

Upstream boundary temperature (°C) = 20; Downstream boundary temperature (°C) = 100; Domain length (m) = 0.1; Uniform axial transport speed (m/s) = 0.0001; Thermal diffusivity (m²/s) = 0.00001; Effective axial conductivity (W/m/K) = 0.6; Evaluation coordinate from boundary 1 (m) = 0.05. Steady local temperature: 50.203254 °C Signed axial conductive heat flux: -460.56834 W/m² Signed length Peclet number: 1 A 0.1 m domain has 20 and 100 °C end temperatures, speed 0.0001 m/s and diffusivity 1e−5 m²/s. At its midpoint, Peclet number 1 gives 50.2033 °C rather than the 60 °C conduction-only midpoint; conductive flux there is −460.568 W/m².