Calculate repeated-pulse junction peaks after thermal accumulation reaches its periodic steady state.

4,000 tools
Periodic semiconductor thermal RC peak calculator — On-state dissipation (W), Thermal resistance (K/W), Thermal time constant (s) and calculation method
Periodic semiconductor thermal RC peak calculator: inputs and calculation method.

How to use this calculator

Calculate repeated-pulse junction peaks after thermal accumulation reaches its periodic steady state.

  1. Enter On-state dissipation (W), Thermal resistance (K/W), Thermal time constant (s), On duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Periodic semiconductor thermal RC peak explained

Repeated power pulses leave stored heat between on intervals. A single-pole thermal model balances heating and cooling over a full period to find the eventual peak and minimum junction temperatures; the duty-weighted power gives a separate average temperature.

Inputs, symbols, and units

P — On-state dissipation (W)
Constant power during each on pulse; zero power between pulses.
Rth — Thermal resistance (K/W)
Single-lump junction-to-ambient thermal resistance.
tau — Thermal time constant (s)
RC thermal time constant.
ton — On duration (s)
Heating portion of each period.
period — Pulse repetition period (s)
Complete on-plus-off duration.
Ta — Ambient temperature (deg C)
Fixed ambient temperature.

Formula and method

ΔT_PEAK=PR_TH(1−exp(−t_ON/τ))/(1−exp(−T/τ)); ΔT_MIN=ΔT_PEAK exp[−(T−t_ON)/τ].

Solve the heating and cooling recurrence over one full cycle. The periodic peak includes heat retained from every earlier pulse.

A worked scenario

On-state dissipation (W) = 20; Thermal resistance (K/W) = 5; Thermal time constant (s) = 2; On duration (s) = 0.2; Pulse repetition period (s) = 1; Ambient temperature (deg C) = 30.

  • Steady periodic peak junction temperature: 54.185514 deg C
  • Steady periodic minimum temperature: 46.212035 deg C
  • Average junction temperature: 50 deg C

A 20 W device with 5 K/W resistance and 2 s thermal time constant pulses for 0.2 s each second; peak temperature exceeds the average-power estimate.

Assumptions and edge cases

One thermal pole, zero off-state power and constant ambient. Actual Foster/Cauer networks or datasheet Zth curves may need multiple modes.

Reading the outputs

Peak and minimum temperatures bracket the periodic cycle; average is based on average power times the thermal resistance.

Frequently asked questions

Is this the first-pulse peak?

No; it is the higher periodic peak reached after many repeated pulses.

When does it reduce to steady heating?

At 100% duty, peak, minimum and average all equal Ta+P Rth.

Can I substitute a datasheet transient curve for tau?

Only after fitting a suitable thermal network; one arbitrary curve point is not a complete time constant.

How do I use the Periodic semiconductor thermal RC peak calculator?

Enter On-state dissipation (W), Thermal resistance (K/W), Thermal time constant (s), On duration (s), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Periodic semiconductor thermal RC peak?

On-state dissipation (W) = 20; Thermal resistance (K/W) = 5; Thermal time constant (s) = 2; On duration (s) = 0.2; Pulse repetition period (s) = 1; Ambient temperature (deg C) = 30. Steady periodic peak junction temperature: 54.185514 deg C Steady periodic minimum temperature: 46.212035 deg C Average junction temperature: 50 deg C A 20 W device with 5 K/W resistance and 2 s thermal time constant pulses for 0.2 s each second; peak temperature exceeds the average-power estimate.