CalcWorldHub
Free online calculator · no signup

Two-device shared heat-sink junction budget calculator

Check how two semiconductor devices heat each other through a common sink while retaining separate junction interfaces.

4,000 tools
Two-device shared heat-sink junction budget calculator — Device 1 dissipation (W), Device 2 dissipation (W), Device 1 junction-to-sink resistance (K/W) and calculation method
Two-device shared heat-sink junction budget calculator: inputs and calculation method.

How to use this calculator

Check how two semiconductor devices heat each other through a common sink while retaining separate junction interfaces.

  1. Enter Device 1 dissipation (W), Device 2 dissipation (W), Device 1 junction-to-sink resistance (K/W), Device 2 junction-to-sink resistance (K/W), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Two-device shared heat-sink junction budget explained

Device 1 junction temperature70.6deg C
Device 1 junction temperature: 70.6 deg C in the worked scenario.

A numerical walkthrough

Device 1 dissipation (W) = 8; Device 2 dissipation (W) = 5; Device 1 junction-to-sink resistance (K/W) = 1.2; Device 2 junction-to-sink resistance (K/W) = 1.8; Shared sink-to-ambient resistance (K/W) = 2; Ambient temperature (deg C) = 35.

  • Device 1 junction temperature: 70.6 deg C
  • Device 2 junction temperature: 70 deg C
  • Shared sink temperature: 61 deg C

An 8 W device and a 5 W device share a 2 K/W sink at 35 °C; the sink reaches 61 °C before individual interface rises are added.

The model behind the numbers

T_S=T_A+(P_1+P_2)R_SA; T_J1=T_S+P_1R_J1S; T_J2=T_S+P_2R_J2S.

Only the sink-to-air path carries both devices heat. Each junction-to-sink path carries its own device power, preventing a common thermal-budget bookkeeping error.

What to enter

P1 — Device 1 dissipation (W)
Heat entering the common sink from first semiconductor.
P2 — Device 2 dissipation (W)
Heat entering the same sink from second semiconductor.
R1 — Device 1 junction-to-sink resistance (K/W)
Series junction-case and interface thermal resistance.
R2 — Device 2 junction-to-sink resistance (K/W)
Series junction-case and interface thermal resistance.
Rsa — Shared sink-to-ambient resistance (K/W)
Installed heat-sink thermal resistance for the total power.
Ta — Ambient temperature (deg C)
Ambient temperature around the shared sink.

Interpreting the result

Isothermal sink lump, fixed thermal resistances and steady dissipation. Spreading resistance and nonuniform sink positions are excluded.

Reading the outputs

Both junction temperatures and the common sink temperature are steady estimates in degrees Celsius.

Frequently asked questions

Should each device use the full sink resistance separately?

Both contribute to a single sink temperature; add that shared rise to each individual interface rise.

Can two devices have different junction-to-sink resistances?

Yes, including different package and interface-pad resistances.

Does this model short overload pulses?

No. Use transient thermal impedance or the periodic thermal-pulse model.

How do I use the Two-device shared heat-sink junction budget calculator?

Enter Device 1 dissipation (W), Device 2 dissipation (W), Device 1 junction-to-sink resistance (K/W), Device 2 junction-to-sink resistance (K/W), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Two-device shared heat-sink junction budget?

Device 1 dissipation (W) = 8; Device 2 dissipation (W) = 5; Device 1 junction-to-sink resistance (K/W) = 1.2; Device 2 junction-to-sink resistance (K/W) = 1.8; Shared sink-to-ambient resistance (K/W) = 2; Ambient temperature (deg C) = 35. Device 1 junction temperature: 70.6 deg C Device 2 junction temperature: 70 deg C Shared sink temperature: 61 deg C An 8 W device and a 5 W device share a 2 K/W sink at 35 °C; the sink reaches 61 °C before individual interface rises are added.