Power factor correction capacitance calculator
Estimate single-phase shunt capacitance for a target reactive power at a chosen AC frequency and voltage. Enter your values below to see the result and method.
inputs.
Related calculators
These tools cover nearby questions while keeping this page focused on its own calculation.
How to use this calculator
Estimate single-phase shunt capacitance for a target reactive power at a chosen AC frequency and voltage.
- Enter Reactive power to compensate (var), Frequency (Hz), RMS voltage (V). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Define the component and operating point
This estimates an ideal single-phase shunt capacitor from reactive vars, frequency, and RMS voltage. Three-phase bank connections and harmonics require separate engineering design. Estimate single-phase shunt capacitance for a target reactive power at a chosen AC frequency and voltage.
Inputs and units
Use the units printed beside each field. These values are Reactive power to compensate (var), Frequency (Hz), RMS voltage (V).
- Reactive power to compensate (var): Reactive power to compensate as defined for the physical or engineering situation.
- Frequency (Hz): Frequency as defined for the physical or engineering situation.
- RMS voltage (V): RMS voltage as defined for the physical or engineering situation.
Design equation and example
C = Q ÷ (2πfV²)
1 kvar at 60 Hz and 240 V requires about 46.0 μF ideal capacitance.
Intermediate values are kept unrounded; the displayed result is rounded for readability.
Applying the result in a system
This estimates an ideal single-phase shunt capacitor from reactive vars, frequency, and RMS voltage. Three-phase bank connections and harmonics require separate engineering design.
Assumptions and limitations
Single-phase ideal-capacitor estimate; three-phase bank connections, voltage rating, harmonics, and switching transients need separate design.
Frequently asked questions
Which measurements belong in the power factor correction capacitance?
Enter Reactive power to compensate (var), Frequency (Hz), RMS voltage (V). Verify that the values use the same operating condition and unit system.
What can make a real installation differ from this power factor correction capacitance estimate?
Single-phase ideal-capacitor estimate; three-phase bank connections, voltage rating, harmonics, and switching transients need separate design.
How do I use the Power factor correction capacitance calculator?
Enter Reactive power to compensate (var), Frequency (Hz), RMS voltage (V). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Power factor correction capacitance?
C = Q ÷ (2πfV²) 1 kvar at 60 Hz and 240 V requires about 46.0 μF ideal capacitance. Intermediate values are kept unrounded; the displayed result is rounded for readability.
What does the Power factor correction capacitance calculator calculate?
Estimate single-phase shunt capacitance for a target reactive power at a chosen AC frequency and voltage.
Read the calculation methodology and privacy policy.