How to use this calculator
Normalize measured photovoltaic energy production by installed DC nameplate capacity.
- Enter Measured PV energy (kWh), Installed DC capacity (kWp), Period length (days). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Specific yield expresses energy output per unit of installed PV capacity for a selected reporting period. The period’s AC energy is divided by the array’s DC nameplate power.
Inputs and units
energyKWh— Measured PV energy (kWh)- Energy generated by the PV system during the period.
capacityKwp— Installed DC capacity (kWp)- PV array DC nameplate capacity.
periodDays— Period length (days)- Calendar days covered by the measured energy.
Formula
Specific yield = PV energy output (kWh) ÷ installed DC capacity (kWp). Daily specific yield = specific yield ÷ period days.
Method
Use measured energy delivered in kWh, installed module nameplate capacity in kWp DC, and the number of calendar days covered. Keep the same system and period in all values.
Worked example
A PV array with 840 kWh output over 30 days and 5 kWp DC capacity has a period yield of 168 kWh/kWp and a daily yield of 5.60 kWh/kWp/day.
Assumptions and limits
This measured-yield metric does not forecast production and does not normalize for irradiance, shading, outages, curtailment, or system losses. Do not compare unlike periods or AC/DC capacity bases without adjustment.
Frequently asked questions
What does specific yield show?
It normalizes measured energy by installed nameplate capacity, making unlike system sizes easier to compare.
Is this the same as capacity factor?
No. Capacity factor also compares energy with the energy possible at rated output over all hours.
Should capacity be AC or DC?
This page uses installed DC nameplate capacity in kWp. Keep that basis consistent when comparing results.
How do I use the PV Specific Yield Calculator?
Enter Measured PV energy (kWh), Installed DC capacity (kWp), Period length (days). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of PV Specific Yield?
A PV array with 840 kWh output over 30 days and 5 kWp DC capacity has a period yield of 168 kWh/kWp and a daily yield of 5.60 kWh/kWp/day.
Reference: technical reference. See our calculation methodology.