How to use this calculator
Compare measured AC energy with the ideal energy implied by rated capacity and plane-of-array irradiation.
- Enter Measured AC energy (kWh), Installed DC capacity (kWp), Plane-of-array irradiation (kWh/m²). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The PV performance ratio (PR) summarizes how much measured energy a system delivered relative to a simple irradiance-based reference. Use the same reporting interval for AC energy and plane-of-array irradiation; use installed DC capacity in kWp.
Inputs and units
energy— Measured AC energy (kWh)- Energy delivered at the selected AC measurement point.
capacity— Installed DC capacity (kWp)- Module nameplate DC capacity under the rating convention used.
irradiation— Plane-of-array irradiation (kWh/m²)- Cumulative irradiation on the array plane over the same interval.
Formula
PR = AC energy (kWh) ÷ [rated DC power (kWp) × plane-of-array irradiation (kWh/m²)].
Worked example
For 10 kWp of DC capacity, 120 kWh/m² irradiation, and 900 kWh measured AC output, reference energy is 1,200 kWh and PR is 75%. Specific yield is 90 kWh/kWp.
Assumptions and limits
This screening ratio is not a weather-normalized guarantee or a substitute for a detailed PV model. Temperature, inverter clipping, downtime, shading, soiling, and measurement boundaries affect results.
Frequently asked questions
Is a higher performance ratio always better?
It indicates more measured energy relative to this reference, but comparisons need matching boundaries, periods, and measurement quality.
Should I use horizontal irradiation?
Use plane-of-array irradiation measured or modeled in the array plane, not horizontal irradiation.
Does this estimate annual energy?
No. It summarizes the entered interval; annual forecasts need weather and system modeling.
How do I use the Solar PV performance ratio calculator?
Enter Measured AC energy (kWh), Installed DC capacity (kWp), Plane-of-array irradiation (kWh/m²). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Solar PV performance ratio?
For 10 kWp of DC capacity, 120 kWh/m² irradiation, and 900 kWh measured AC output, reference energy is 1,200 kWh and PR is 75%. Specific yield is 90 kWh/kWp.
Reference: technical reference. See our calculation methodology.