CalcWorldHub
Free online calculator · no signup

Rectangular gradually varied backwater profile calculator

Integrate a steady rectangular backwater profile from an entered boundary instead of treating every section as uniform flow.

4,000 tools
Rectangular gradually varied backwater profile calculator — Discharge (m³/s), Bed width (m), Manning roughness (s/m^(1/3)) and calculation method
Rectangular gradually varied backwater profile calculator: inputs and calculation method.

How to use this calculator

Integrate a steady rectangular backwater profile from an entered boundary instead of treating every section as uniform flow.

  1. Enter Discharge (m³/s), Bed width (m), Manning roughness (s/m^(1/3)), Bed slope, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Rectangular gradually varied backwater profile explained

Integrate a steady rectangular backwater profile from an entered boundary instead of treating every section as uniform flow.

Depth at end of reach1.9783m
Depth at end of reach: 1.978282 m in the worked scenario.

How the calculation works

dy/dx=(S0−Sf)/(1−Fr²); Sf=[nQ/(AR^(2/3))]²; Fr²=Q²/(gb²y³).

Downstream x is positive. For subcritical backwater a downstream control is commonly integrated upstream using a negative distance. The numerical path must remain away from the critical singularity.

Set up the calculation

Q — Discharge (m³/s)
Constant discharge along the prismatic reach.
b — Bed width (m)
Constant rectangular channel width.
n — Manning roughness (s/m^(1/3))
SI Manning coefficient for the bed and walls.
S — Bed slope
Positive bed fall per unit distance in the downstream direction.
y0 — Boundary water depth (m)
Known depth at x=0.
L — Signed downstream distance (m)
Negative distance integrates upstream from a downstream boundary; positive distance integrates downstream.
N — Integration steps
Number of fourth-order Runge–Kutta steps; refine it to inspect numerical stability. Enter a whole number.

Limits of this model

Steady prismatic gradually varied flow, hydrostatic pressure, constant Q and no jumps or lateral inflow. Step refinement is necessary near rapidly changing states. Educational model; this is not a code-compliant design check.

Check this example

Discharge (m³/s) = 10; Bed width (m) = 5; Manning roughness (s/m^(1/3)) = 0.03; Bed slope = 0.001; Boundary water depth (m) = 2; Signed downstream distance (m) = -100; Integration steps = 200.

  • Depth at end of reach: 1.978282 m
  • Depth change: -0.021718 m
  • End Froude number: 0.229529

A 5 m wide reach carries 10 m³/s with n=0.03 and bed slope 0.001. Starting at a 2 m downstream depth, the default calculation follows 100 m upstream.

Reading the outputs

Final and changed depths are m; the final Froude number diagnoses the calculated flow regime.

Frequently asked questions

Why can integration direction matter?

The correct boundary lies downstream for many subcritical profiles and upstream for many supercritical profiles.

What happens near Fr=1?

The differential equation is singular; a critical control or rapidly varied model is needed and the calculation rejects the path.

Does this include flood-wave travel time?

No. It is a steady profile, not an unsteady Saint-Venant solution.

How do I use the Rectangular gradually varied backwater profile calculator?

Enter Discharge (m³/s), Bed width (m), Manning roughness (s/m^(1/3)), Bed slope, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Rectangular gradually varied backwater profile?

Discharge (m³/s) = 10; Bed width (m) = 5; Manning roughness (s/m^(1/3)) = 0.03; Bed slope = 0.001; Boundary water depth (m) = 2; Signed downstream distance (m) = -100; Integration steps = 200. Depth at end of reach: 1.978282 m Depth change: -0.021718 m End Froude number: 0.229529 A 5 m wide reach carries 10 m³/s with n=0.03 and bed slope 0.001. Starting at a 2 m downstream depth, the default calculation follows 100 m upstream.