CalcWorldHub
Free online calculator · no signup

Resonator transverse mode frequency separation calculator

Estimate the frequency offset between transverse resonator mode families from cavity stability and Gouy phase.

4,000 tools
Resonator transverse mode frequency separation calculator — Cavity length (m), First stability parameter, Second stability parameter and calculation method
Resonator transverse mode frequency separation calculator: inputs and calculation method.

How to use this calculator

Estimate the frequency offset between transverse resonator mode families from cavity stability and Gouy phase.

  1. Enter Cavity length (m), First stability parameter, Second stability parameter, Transverse order difference. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Resonator transverse mode frequency separation explained

Transverse order frequency separation166.5514MHz
Transverse order frequency separation: 166.551366 MHz in the worked scenario.

A numerical walkthrough

Cavity length (m) = 0.3; First stability parameter = 0.5; Second stability parameter = 0.5; Transverse order difference = 1.

  • Transverse order frequency separation: 166.551366 MHz
  • Longitudinal free spectral range: 499.654097 MHz
  • One way Gouy phase: 1.047198 radians

For g1=g2=0.5, the one-way Gouy phase is π/3 and adjacent transverse orders are separated by one third of the longitudinal FSR.

The model behind the numbers

Δν=Δ(m+n)·FSR·acos(±√g₁g₂)/π, FSR=c/(2L); use the negative root when both g values are negative.

The signed-root convention retains the branch difference between near-planar and near-concentric cavities. Mode offsets can coincide modulo a longitudinal FSR.

What to enter

length — Cavity length (m)
Mirror separation in air.
g1 — First stability parameter
g1=1−L/R1 for the first mirror.
g2 — Second stability parameter
g2=1−L/R2 for the second mirror.
order — Transverse order difference
Difference in m+n mode order. Enter a whole number.

Interpreting the result

Empty paraxial cavity in air, stable away from degeneracy. Astigmatic cavities need separate tangential and sagittal phases.

Reading the outputs

Transverse separation and FSR are megahertz. Gouy phase is radians.

Frequently asked questions

Why does the square-root sign matter?

It selects the near-planar versus near-concentric Gouy-phase branch.

Can transverse modes overlap another longitudinal family?

Yes. Offsets are physically compared modulo the longitudinal FSR.

Does this include astigmatism?

No. One common stability pair is assumed.

How do I use the Resonator transverse mode frequency separation calculator?

Enter Cavity length (m), First stability parameter, Second stability parameter, Transverse order difference. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Resonator transverse mode frequency separation?

Cavity length (m) = 0.3; First stability parameter = 0.5; Second stability parameter = 0.5; Transverse order difference = 1. Transverse order frequency separation: 166.551366 MHz Longitudinal free spectral range: 499.654097 MHz One way Gouy phase: 1.047198 radians For g1=g2=0.5, the one-way Gouy phase is π/3 and adjacent transverse orders are separated by one third of the longitudinal FSR.