How to use this calculator
Calculate a curved temperature profile when wall conductivity changes with temperature instead of assuming a straight line.
- Enter Wall thickness (m), Conductivity at reference temperature (W/m/K), Linear conductivity temperature coefficient (1/K), Conductivity reference temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Temperature dependent conductivity wall profile explained
A numerical walkthrough
Wall thickness (m) = 0.1; Conductivity at reference temperature (W/m/K) = 2; Linear conductivity temperature coefficient (1/K) = 0.005; Conductivity reference temperature (°C) = 20; Left face temperature (°C) = 120; Right face temperature (°C) = 20; Location from left face (m) = 0.05.
- Signed wall heat flux: 2500 W/m²
- Temperature at location: 74.950976 °C
- Equivalent interval conductivity: 2.5 W/m/K
Across a 0.1 m wall from 120 to 20 °C, conductivity k=2[1+0.005(T−20)] W/m/K produces 2,500 W/m². The midpoint is 74.9510 °C rather than the arithmetic 70 °C because the hot side conducts better.
The model behind the numbers
k(T)=k₀[1+b(T−Tr)]; q″L=∫T₂^T₁ k(T)dT; ∫Tr^T(x)k(T)dT=∫Tr^T₁k(T)dT−q″x.
Integrate conductivity over the face-temperature interval to determine constant steady flux, then invert the integrated conductivity at the selected depth.
What to enter
L— Wall thickness (m)- Wall thickness (m). Enter the value for this state; the units shown are used without an unstated conversion.
k0— Conductivity at reference temperature (W/m/K)- Conductivity at reference temperature (W/m/K). Enter the value for this state; the units shown are used without an unstated conversion.
b— Linear conductivity temperature coefficient (1/K)- Linear conductivity temperature coefficient (1/K). Enter the value for this state; the units shown are used without an unstated conversion.
Tr— Conductivity reference temperature (°C)- Conductivity reference temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T1— Left face temperature (°C)- Left face temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
T2— Right face temperature (°C)- Right face temperature (°C). Enter the value for this state; the units shown are used without an unstated conversion.
x— Location from left face (m)- Location from left face (m). Enter the value for this state; the units shown are used without an unstated conversion.
Interpreting the result
One-dimensional steady wall with no internal source and a linear positive k(T) fit over the entire temperature range.
Reading the outputs
Flux is positive left to right, temperature is local and equivalent conductivity reproduces the same face-to-face heat rate.
Frequently asked questions
Is the midpoint temperature the mean of face temperatures?
Only for constant conductivity; variable conductivity generally makes the profile nonlinear.
Can the temperature coefficient be negative?
Yes, provided conductivity stays positive across both face temperatures.
What does equivalent conductivity mean?
It is the integral average over temperature, not a material constant valid outside that interval.
How do I use the Temperature dependent conductivity wall profile calculator?
Enter Wall thickness (m), Conductivity at reference temperature (W/m/K), Linear conductivity temperature coefficient (1/K), Conductivity reference temperature (°C), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Temperature dependent conductivity wall profile?
Wall thickness (m) = 0.1; Conductivity at reference temperature (W/m/K) = 2; Linear conductivity temperature coefficient (1/K) = 0.005; Conductivity reference temperature (°C) = 20; Left face temperature (°C) = 120; Right face temperature (°C) = 20; Location from left face (m) = 0.05. Signed wall heat flux: 2500 W/m² Temperature at location: 74.950976 °C Equivalent interval conductivity: 2.5 W/m/K Across a 0.1 m wall from 120 to 20 °C, conductivity k=2[1+0.005(T−20)] W/m/K produces 2,500 W/m². The midpoint is 74.9510 °C rather than the arithmetic 70 °C because the hot side conducts better.
Read our calculation methodology.