How to use this calculator
Calculate water TDS from the dried filtrate residue and the original filtered volume.
- Enter Dry residue plus dish, A (mg), Clean dish tare, B (mg), Original sample volume filtered, C (mL). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
Enter the dried residue-plus-dish mass, the clean evaporating-dish tare, and the volume of filtrate represented. The result follows EPA Method 160.1 and is reported in mg/L.
Inputs and units
residuePlusDishMg— Dry residue plus dish, A (mg)- Mass of the evaporating dish with the dried filterable residue.
dishTareMg— Clean dish tare, B (mg)- Mass of the same clean evaporating dish before adding filtrate.
filteredSampleVolumeMl— Original sample volume filtered, C (mL)- Volume of the original sample represented by the evaporated filtrate.
Formula
TDS (mg/L) = (A − B) × 1,000 / C, where A is dried filterable residue plus dish mass, B is the clean dish tare, both in mg, and C is the filtered sample volume represented in mL.
Method
Subtract the evaporating-dish tare from the mass of the dried filtrate residue and dish. Convert milliliters of original sample to liters by multiplying the mass difference by 1,000 and dividing by the represented volume.
Worked example
A dish plus dried filtrate residue weighs 104 mg; the clean dish tare is 100 mg, and the filtrate represents 200 mL of original sample. TDS = (104 − 100) × 1,000 / 200 = 20 mg/L.
Assumptions and limits
This calculation assumes the measured filtrate volume represents the stated original sample volume and that the dish is clean, dry, and weighed consistently. EPA Method 160.1 defines filterable residue by filtration, evaporation, and drying at 180 °C. It does not estimate dissolved solids from conductivity.
Frequently asked questions
What does filterable residue mean?
It is the residue remaining after a sample is filtered, evaporated, and dried under the selected analytical method.
Why is TDS different from TSS?
TDS is measured from the filtrate that passed through the filter; TSS is measured from residue retained on the filter.
Can conductivity be used to calculate this result?
This page uses a gravimetric residue measurement. Conductivity-based estimates require a sample-specific conversion factor and are not equivalent to the EPA mass method.
How do I use the Total Dissolved Solids (TDS) from Filterable Residue Calculator?
Enter Dry residue plus dish, A (mg), Clean dish tare, B (mg), Original sample volume filtered, C (mL). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Total Dissolved Solids (TDS) from Filterable Residue?
A dish plus dried filtrate residue weighs 104 mg; the clean dish tare is 100 mg, and the filtrate represents 200 mL of original sample. TDS = (104 − 100) × 1,000 / 200 = 20 mg/L.
Reference: U.S. EPA Method 160.1 filterable residue gravimetric calculation. See our calculation methodology.