Transformer winding window copper-fill check calculator

Test whether selected wire diameters and turn counts are plausible within a transformer or inductor winding window.

4,000 tools
Transformer winding window copper-fill check calculator — Turns by winding, Bare wire diameters (m), Available winding window area (m2) and calculation method
Transformer winding window copper-fill check calculator: inputs and calculation method.

How to use this calculator

Test whether selected wire diameters and turn counts are plausible within a transformer or inductor winding window.

  1. Enter Turns by winding, Bare wire diameters (m), Available winding window area (m2), Allowed bare-copper fill fraction. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Calculation guide

Transformer winding window copper-fill check explained

Bare-copper window fill50.5796%
Bare-copper window fill: 50.579642 % in the worked scenario.

How the calculation works

A_CU=ΣN_i πd_i²/4; k_FILL=A_CU/A_WINDOW; A_REQUIRED=A_CU/k_ALLOWED.

Use bare copper diameter because the chosen practical fill allowance already reserves room for enamel, insulation, winding structure and packing gaps.

Set up the calculation

turns — Turns by winding
Integer turn counts in each winding. Use comma-separated values in the stated order.
diam — Bare wire diameters (m)
Conductor diameters paired with each winding; omit insulation here. Use comma-separated values in the stated order.
Aw — Available winding window area (m2)
Usable cross-sectional winding window after bobbin and margins.
fill — Allowed bare-copper fill fraction
Chosen practical copper/window limit for insulation and packing.

Limits of this model

Area screening only; insulation distances, layered packing, terminals, thermal rise and proximity loss require separate checks.

Check this example

Turns by winding = 100,20; Bare wire diameters (m) = 0.0004,0.0009; Available winding window area (m2) = 0.00005; Allowed bare-copper fill fraction = 0.35.

  • Bare-copper window fill: 50.579642 %
  • Required window at chosen fill: 0.000072 m2
  • Allowed-fill utilization: 144.513262 %

One hundred turns of 0.4 mm wire plus twenty turns of 0.9 mm wire compete for a 50 mm² available window at a 35% copper-fill allowance.

Reading the outputs

Bare-copper fill and utilization are distinct: utilization compares actual copper with the allowed fraction, not with the entire geometric window.

Frequently asked questions

Should insulated diameter be used?

Not with a bare-copper fill allowance; use one internally consistent convention.

Does utilization below 100% guarantee windability?

No; winding layer arrangement and required insulation can still prevent assembly.

Can litz wire use its overall bundle diameter?

Use total copper area per turn or an equivalent copper diameter, then account for practical bundle packing.

How do I use the Transformer winding window copper-fill check calculator?

Enter Turns by winding, Bare wire diameters (m), Available winding window area (m2), Allowed bare-copper fill fraction. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Transformer winding window copper-fill check?

Turns by winding = 100,20; Bare wire diameters (m) = 0.0004,0.0009; Available winding window area (m2) = 0.00005; Allowed bare-copper fill fraction = 0.35. Bare-copper window fill: 50.579642 % Required window at chosen fill: 0.000072 m2 Allowed-fill utilization: 144.513262 % One hundred turns of 0.4 mm wire plus twenty turns of 0.9 mm wire compete for a 50 mm² available window at a 35% copper-fill allowance.