How to use this calculator
Estimate event recharge depth and volume from a recession-corrected water-table rise, specific yield, and a stated aquifer area.
- Enter Aquifer specific yield (fraction), Recession-corrected water-table rise (mm), Area used to scale recharge volume (ha). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How this calculation works
The water-table fluctuation method estimates groundwater recharge by multiplying specific yield by the water-level rise attributed to recharge. The rise should be measured above the level the well hydrograph would have reached if the pre-event recession had continued. An optional area converts the estimated depth to a volume.
Inputs and units
specificYield— Aquifer specific yield (fraction)- Dimensionless drainable-water fraction; enter 0.18 for 18%.
correctedRiseMm— Recession-corrected water-table rise (mm)- Peak rise above the estimated no-recharge recession level for the event.
areaHa— Area used to scale recharge volume (ha)- Area over which the point recharge depth is assumed uniform for the volume estimate.
Formula
Recharge depth = specific yield × recession-corrected water-table rise. Recharge volume = recharge depth × entered area.
Method
Enter a dimensionless specific yield from 0 to 1, a positive corrected rise in millimeters, and the area over which you want to scale the estimate. Convert millimeters to meters and hectares to square meters for volume.
Worked example
A corrected 120 mm rise with specific yield 0.18 gives 21.60 mm of estimated recharge. Scaled across 10 ha, that is 2,160 m³.
Assumptions and limits
The method assumes the measured shallow-well rise is caused by recharge and specific yield is known and stable. It is a simplified point estimate; pumping, delayed drainage, other water-level drivers, and spatial variability affect reliability.
Frequently asked questions
What does recession-corrected mean?
It is the observed peak level minus the level expected if the pre-recharge recession had continued without the event.
Is this a regional recharge measurement?
No. It estimates recharge associated with the monitored well; scaling the depth across an area adds a uniformity assumption.
Why is specific yield required?
It converts a water-table rise into an equivalent volume of water released from or added to the aquifer per unit area.
How do I use the Water-Table Fluctuation Groundwater Recharge Calculator?
Enter Aquifer specific yield (fraction), Recession-corrected water-table rise (mm), Area used to scale recharge volume (ha). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Water-Table Fluctuation Groundwater Recharge?
A corrected 120 mm rise with specific yield 0.18 gives 21.60 mm of estimated recharge. Scaled across 10 ha, that is 2,160 m³.
Reference: U.S. Geological Survey water-table-fluctuation recharge method. See our calculation methodology.