How to use this calculator
Locate a recharge-supported water table and its groundwater divide between two unequal maintained drain heads.
- Enter Horizontal hydraulic conductivity (m/day), Boundary separation (m), Left boundary saturated thickness (m), Right boundary saturated thickness (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Recharge driven water table between unequal drains explained
For steady Dupuit flow between drains, the squared water-table elevation is quadratic in distance under uniform recharge. The boundary heads set the profile slope; the recharge rate sets the divide location and signed discharge.
Inputs, symbols, and units
K— Horizontal hydraulic conductivity (m/day)- Uniform unconfined conductivity over a horizontal impermeable base.
L— Boundary separation (m)- Horizontal distance between two maintained water-level boundaries.
h0— Left boundary saturated thickness (m)- Water elevation above the aquifer base at x=0.
hL— Right boundary saturated thickness (m)- Water elevation above the base at x=L.
N— Uniform net recharge (mm/day)- Recharge reaching the water table, after evapotranspiration or other losses.
x— Evaluation distance from left (m)- Point within the interval from zero to L.
Formula and method
h²=h0²+Bx−Nx²/K; B=(hL²−h0²)/L+NL/K; qx=−KB/2+Nx; xdivide=KB/(2N), with N in m/day.
Discharge is positive to the right. A zero-flow coordinate outside the interval means recharge is too small to create an interior divide under the boundary-head gradient.
A worked scenario
Horizontal hydraulic conductivity (m/day) = 2; Boundary separation (m) = 100; Left boundary saturated thickness (m) = 2; Right boundary saturated thickness (m) = 3; Uniform net recharge (mm/day) = 2; Evaluation distance from left (m) = 40.
- Local saturated thickness: 2.898275 m
- Signed rightward discharge per width: -0.07 m²/day
- Divide coordinate or external zero-flow coordinate: 75 m
- Left-boundary rightward discharge: -0.15 m²/day
Two drains 100 m apart maintain 2 and 3 m saturated thickness. Recharge of 2 mm/day enters K=2 m/day material; the local water table is evaluated 40 m from the left drain.
Assumptions and edge cases
Steady horizontal Dupuit flow, uniform recharge and a flat base. When recharge is zero there is no unique divide; the displayed sentinel is not a physical interior divide. Educational model; this is not a code-compliant design check.
Reading the outputs
Water-table thickness and divide coordinate are m; discharges are m²/day per metre of drain length. Zero recharge returns divide coordinate zero as a stated no-divide sentinel.
Frequently asked questions
Can the divide lie beyond a boundary?
Yes mathematically; that indicates no interior divide and flow toward one boundary throughout the interval.
Is recharge the same as rainfall?
Only the part reaching groundwater belongs here; surface runoff and soil storage changes are excluded.
Why does zero recharge show zero for the divide?
It is an explicitly documented no-divide sentinel; the discharge result remains the physical head-gradient flow.
How do I use the Recharge driven water table between unequal drains calculator?
Enter Horizontal hydraulic conductivity (m/day), Boundary separation (m), Left boundary saturated thickness (m), Right boundary saturated thickness (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Recharge driven water table between unequal drains?
Horizontal hydraulic conductivity (m/day) = 2; Boundary separation (m) = 100; Left boundary saturated thickness (m) = 2; Right boundary saturated thickness (m) = 3; Uniform net recharge (mm/day) = 2; Evaluation distance from left (m) = 40. Local saturated thickness: 2.898275 m Signed rightward discharge per width: -0.07 m²/day Divide coordinate or external zero-flow coordinate: 75 m Left-boundary rightward discharge: -0.15 m²/day Two drains 100 m apart maintain 2 and 3 m saturated thickness. Recharge of 2 mm/day enters K=2 m/day material; the local water table is evaluated 40 m from the left drain.
Read our calculation methodology.