Windowed sinc FIR filter design calculator
Generate finite impulse response coefficients by windowing an ideal sinc response for the chosen pass type, cutoff, sample rate, tap count, and window.
How to use this calculator
Generate finite impulse response coefficients by windowing an ideal sinc response for the chosen pass type, cutoff, sample rate, tap count, and window.
- Enter Odd tap count, Cutoff frequency (Hz), Sampling rate (Hz), Filter type, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
How the Windowed sinc FIR filter design calculator works
Generate finite impulse response coefficients by windowing an ideal sinc response for the chosen pass type, cutoff, sample rate, tap count, and window.
Inputs and units
- Odd tap count: Odd number of FIR taps; it sets coefficient length and design order.
- Cutoff frequency (Hz): Chosen filter cutoff in hertz; it must be below Nyquist for the selected sampling rate.
- Sampling rate (Hz): Digital sampling frequency in samples per second; Nyquist is half this value.
- Filter type: Pass type selected for the FIR design, such as low-pass or high-pass.
- Window: Window function applied to the ideal sinc coefficients.
Formula and method
h[n] ∝ hᵢdeal[n]·w[n], then normalize according to the selected design; an odd tap count gives a symmetric linear-phase FIR
Worked example
With 31 taps, a 5 kHz low-pass cutoff, 48 kHz sampling, and a Hamming window, the output contains 31 symmetric coefficients; the normalized cutoff is 5/24≈0.2083 of Nyquist.
Interpreting the result
The coefficients define a discrete-time filter. Tap count controls length and transition sharpness; window choice trades sidelobe suppression against transition width.
Assumptions and limits
Cutoff must lie below Nyquist (fs/2); the finite window makes the transition band nonzero. This design does not model fixed-point quantization, passband requirements, or an application-specific stability/latency budget.
Sources and method
- Describes window-method FIR design, cutoff frequency, windows, and tap count. SciPy signal.firwin documentation
Frequently asked questions
Why must cutoff be below half the sampling rate?
The Nyquist frequency is fs/2; a digital low-pass cutoff must lie below that limit for this design.
What changes when I choose a different window?
The window changes the finite impulse response's sidelobes and transition width; coefficient count and cutoff also shape the response.
How do I use the Windowed sinc FIR filter design calculator?
Enter Odd tap count, Cutoff frequency (Hz), Sampling rate (Hz), Filter type, then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Windowed sinc FIR filter design?
With 31 taps, a 5 kHz low-pass cutoff, 48 kHz sampling, and a Hamming window, the output contains 31 symmetric coefficients; the normalized cutoff is 5/24≈0.2083 of Nyquist.
What does the Windowed sinc FIR filter design calculator calculate?
Generate finite impulse response coefficients by windowing an ideal sinc response for the chosen pass type, cutoff, sample rate, tap count, and window.
See the calculation methodology.