Use the same operating point
Enter open-circuit voltage in volts, internal resistance in milliohms, and positive discharge current in amperes. The resistance is converted to ohms by dividing by 1,000 before it is multiplied by current. A resistance of 40 mΩ is 0.040 Ω. The resistance estimate should match the battery’s state of charge, temperature, age, and measurement method as closely as possible.
The calculator permits nonnegative resistance and current, requires nonzero open-circuit voltage, and rejects a result below zero terminal voltage. Zero current means no modeled sag or internal loss. Its input is a positive load-current magnitude; do not enter a negative current to represent charging, because the model is designed for discharge.
Follow the electrical equations
Voltage drop = current × resistance. Loaded voltage = open-circuit voltage − voltage drop. Resistive loss power = current² × resistance. The square in the last equation means loss rises quickly with current: doubling current doubles the voltage drop but quadruples this modeled I²R power at a fixed resistance.
For a 12.6 V source, 40 mΩ resistance, and 10 A current, the resistance is 0.040 Ω, drop is 0.40 V, loaded estimate is 12.20 V, and internal loss is 4 W. Keep the resistance units visible because entering 40 as though it were ohms instead of milliohms would produce a radically different and invalid result.
Interpret voltage and heat separately
Loaded terminal voltage estimates the battery-side voltage under the stated current. It is not the voltage at a distant appliance if cable, connector, fuse, and switch resistance are excluded. A device may have its own low-voltage cutoff, and a current-controlled load can draw more current as voltage falls; this tool does not iterate a constant-power load.
The loss-power output is the instantaneous rate of heat generation in the internal resistance model, not the total energy lost over a run. To estimate energy, the current and resistance would need to be integrated over time, and both may change during discharge. Do not treat a single I²R value as a battery temperature rise or thermal-safety conclusion.
Check two load cases
At 12.6 V, 40 mΩ, and 10 A, the drop is 0.40 V and the terminal estimate is 12.20 V, while I²R loss is 4 W. At 25.6 V, 18 mΩ, and 35 A, the drop is 0.63 V, the loaded estimate is 24.97 V, and loss power is 22.05 W.
Outputs are displayed to four decimal places: loaded volts, sag volts, and watts. Extra digits only preserve arithmetic detail. Battery voltage moves with state of charge and load, and equivalent resistance may vary with pulse duration. Compare with a measured voltage at the same operating point rather than assuming that a fixed resistance describes every condition.
Worked examples
12 V battery at a 10 A load
Inputs: Open-circuit voltage 12.6 V; resistance 40 mΩ; current 10 A.
Calculation: R = 40 ÷ 1000 = 0.040 Ω; drop = 10 × 0.040 = 0.40 V; loaded = 12.6 − 0.40 = 12.20 V; loss = 10² × 0.040 = 4 W.
Estimated terminal voltage is 12.2000 V, sag 0.4000 V, and internal-resistance loss 4.0000 W.
Higher-current 24 V system
Inputs: Open-circuit voltage 25.6 V; resistance 18 mΩ; current 35 A.
Calculation: R = 18 ÷ 1000 = 0.018 Ω; drop = 35 × 0.018 = 0.63 V; loaded = 25.6 − 0.63 = 24.97 V; loss = 35² × 0.018 = 22.05 W.
The estimate is 24.9700 V loaded, 0.6300 V sag, and 22.0500 W internal loss.
Use the estimate as a diagnostic clue
A large predicted drop can flag a need to verify the current estimate, connections, battery condition, or equivalent-resistance measurement. It cannot isolate the cause. Contact resistance in a loose connection, cable gauge, temperature, and a battery’s internal electrochemistry can all contribute to observed voltage behavior.
Use a manufacturer’s datasheet or a controlled test for resistance and voltage limits, then separately check protection and wiring. The calculator does not model a BMS, fuses, current pulses, cell imbalance, constant-power loads, or state-of-charge recovery. Do not use its result as permission to exceed current limits or as a safety assessment.