Calculate the energy between SOC targets
Starting and target state of charge are percentages of usable battery capacity. The energy added is capacity × (target SOC − starting SOC) ÷ 100. A 60 kWh battery moving from 20% to 70% needs 30 kWh stored in the battery under this simple proportional model. The percentage difference, not the final percentage alone, determines the energy increment.
Use the same capacity basis for both SOC readings. If a vehicle reports a displayed usable capacity that differs from its original gross pack rating, the usable value is the relevant input for this estimate. The model does not infer degradation or reserve buffers; it simply applies the entered SOC change to entered usable capacity.
Include charging efficiency and average power
Wall-to-battery efficiency is entered as a percentage. Divide battery energy by that fraction to estimate energy drawn from the supply, then divide by average charger power in kW to get hours. At 90% efficiency, storing 30 kWh requires about 33.333 kWh from the wall. At 10 kW average power, the idealized time is about 3.333 hours.
The power field is average power actually delivered during the interval, not automatically the label printed on a charging unit. Vehicle limits, site limits, shared equipment, and charging conditions can reduce delivered power. Efficiency must be positive, target SOC cannot be below starting SOC, and the SOC inputs must remain within 0% to 100%.
Understand the constant-average model
The calculation uses one average power and one efficiency value for the whole interval. Real charging curves are not usually flat: power can vary with battery temperature, state of charge, vehicle limits, charger capability, and site conditions. The estimate therefore answers a specific question: how long would the energy interval take if the stated average conditions held throughout?
If a manufacturer or charging record gives a measured average for the same vehicle and SOC window, use it instead of the station’s maximum rating. Comparing two options works best when capacity, SOC endpoints, and efficiency assumptions are held constant. Changing several inputs at once makes it harder to see which assumption caused a different result.
Use the result to compare sessions
For planning, calculate the energy increment first, then compare the time under plausible average-power scenarios. A low-power home session may fit overnight even when it is much slower than a public fast-charge stop. The estimate can also expose a unit error: kWh measures energy, kW measures power, and their ratio gives hours.
Do not use the result as a promise of departure time. A charging stop also includes connection time, payment or access delays, thermal preparation, tapering, interruptions, and the time needed to reach a suitable charger. Those activities are outside this equation and may matter more than a small change in the modeled efficiency.
Limits and safety context
The U.S. Department of Energy’s Alternative Fuels Data Center notes that charging time depends on battery state, battery capacity, vehicle charging limits, charging equipment, and electrical service. That context is why a simple average-power calculation should be treated as an estimate. The calculator does not select equipment, test an electrical circuit, or certify a charging installation.
Use the vehicle manual and qualified electrical guidance for equipment and installation decisions. The output is useful for comparing a defined SOC interval under transparent assumptions; actual time can be longer when power tapers or conditions reduce delivery. It does not estimate battery health, cell balancing, thermal limits, or charging cost.
Worked examples
Both calculations distinguish energy stored in the battery from energy drawn at the wall.
Home charging from 20% to 70%
Inputs: Usable capacity = 60 kWh; SOC = 20% to 70%; average power = 10 kW; efficiency = 90%.
Calculation: Battery energy = 60 × (70 − 20) ÷ 100 = 30 kWh; wall energy = 30 ÷ 0.90 = 33.333… kWh; time = 33.333… ÷ 10 = 3.333333 h.
The model reports 30 kWh added to the battery and about 3.333333 hours at the stated average power. Wall draw is about 33.333 kWh before any separately billed site charges.
A higher-power session to the same SOC span
Inputs: Usable capacity = 72 kWh; SOC = 25% to 75%; average power = 24 kW; efficiency = 80%.
Calculation: Battery energy = 72 × (75 − 25) ÷ 100 = 36 kWh; wall energy = 36 ÷ 0.80 = 45 kWh; time = 45 ÷ 24 = 1.875 h.
The modeled session stores 36 kWh in 1.875 hours under the entered constant average. Its lower efficiency means 45 kWh is drawn from the wall; this is an energy comparison, not an equipment recommendation.