Separate dead-time and recovery mechanisms
Dead time is the interval after one switch turns off and before its complementary switch turns on. The pause helps prevent shoot-through, but an inductive load still needs a current path. In a silicon half bridge, that current may flow through a MOSFET body diode at a forward drop above the channel’s on-state drop.
When the opposite switch turns on, stored charge in a conducting diode can be removed as reverse-recovery charge. That current pulse is distinct from ordinary load current and can raise turn-on loss and voltage stress. The calculator estimates the two average-power contributions separately so the timing penalty and charge-recovery penalty are visible.
Use the calculator’s per-cycle equations
The dead-time term is Pdead = 2 I Vf td fs. I is the assumed constant commutating-current magnitude in amperes, Vf is body-diode drop in volts, td is dead time per transition in seconds, and fs is complete switching cycles per second. The factor of two represents two dead-time intervals each cycle.
The recovery estimate is Prr ≈ nrr Qrr Vbus fs. Qrr is recovered charge per hard-recovery event in coulombs, Vbus is the commutation voltage, and nrr is the integer number of events per cycle from zero to two. The total is their sum. The runtime requires 2tdfs < 1 so the two dead-time intervals do not fill a full period.
Compare two switching cases
For 8 A, Vf = 0.9 V, td = 80 ns, fs = 200 kHz, Qrr = 50 nC, Vbus = 48 V, and one recovery event, the dead-time term is 2 × 8 × 0.9 × 80 ns × 200 kHz = 0.2304 W. Recovery contributes 50 nC × 48 V × 200 kHz = 0.48 W, so the combined estimate is 0.7104 W.
At 4 A, 1.0 V, 50 ns, 100 kHz, 25 nC, 24 V, and two recovery events, dead-time loss is 0.040 W and recovery loss is 0.120 W, for 0.160 W. This comparison shows how frequency multiplies both terms, while event count scales only the recovery estimate.
Worked examples
One recovery event per cycle
Inputs: I = 8 A, Vf = 0.9 V, td = 80 ns, fs = 200 kHz, Qrr = 50 nC, Vbus = 48 V, events = 1.
Calculation: Pdead = 2 × 8 × 0.9 × 80 × 10⁻⁹ × 200,000 = 0.2304 W; Prr = 1 × 50 × 10⁻⁹ × 48 × 200,000 = 0.48 W; total = 0.7104 W.
The event contributes 0.48 W in this estimate, more than the dead-time conduction term for these inputs.
Two recovery events with a lower bus and frequency
Inputs: I = 4 A, Vf = 1.0 V, td = 50 ns, fs = 100 kHz, Qrr = 25 nC, Vbus = 24 V, events = 2.
Calculation: Pdead = 2 × 4 × 1.0 × 50 × 10⁻⁹ × 100,000 = 0.040 W; Prr = 2 × 25 × 10⁻⁹ × 24 × 100,000 = 0.120 W; total = 0.160 W.
The event count doubles recovery loss relative to one such event with the same charge, voltage, and frequency.
Choose inputs from the actual transition
Use dead time per transition, not the sum of both intervals; the formula already includes two. Use the current magnitude during dead time, not automatically the cycle-average or RMS load current. For a current that changes substantially within the interval, the constant-current estimate should be interpreted as an approximation to the time integral of diode voltage times current.
Qrr must correspond to the diode and its forward current, reverse voltage, temperature, and current slew rate. Datasheets often specify charge under a particular test circuit. A value from a different condition can materially change the estimated recovery term, so keep those test conditions with the input value.
Read the total as an added-loss budget
The output is an added half-bridge loss estimate for the entered dead-time and recovery terms. It does not replace MOSFET conduction loss, voltage-current overlap loss, gate-drive power, output-capacitance energy, or driver quiescent power. Add each relevant term once when making a total converter budget.
A value of zero events suppresses the recovery term in the model; it does not prove that a real diode has zero stored charge. Likewise, a negative load current is not represented because the input is a magnitude. Check the direction of current and which diode conducts in the actual commutation sequence.
Validate timing and device behavior
Measure switch-node voltage and device current with suitable probes and safe bandwidth. Compare actual diode conduction interval with the commanded dead time: propagation delays, gate resistance, temperature, and device turn-off tail can make them different. Check reverse-recovery overshoot and ringing as well as average input power.
The equations assume constant diode drop and current during dead time and represent recovery energy as QrrVbus per event. They omit soft switching, nonlinear voltage-current overlap, temperature-dependent recovery shape, parasitic inductance, and shoot-through. Use the device and driver datasheets or a validated switching model for stress and thermal decisions.