Choose the reference point for the head
Enter vertical water head in metres and fluid density in kilograms per cubic metre. Head is the vertical separation from the free surface to the point where pressure is being estimated, measured in the same connected static fluid. It is not pipe length or the distance traveled along a sloped route.
The calculator accepts head from zero through 100,000 m, but fluid density must be greater than zero and no more than 20,000 kg/m³. A zero head gives zero pressure. For ordinary water, 1,000 kg/m³ is a common approximate input, while actual density depends on fluid composition and temperature.
Hydrostatic formula and output units
Gauge pressure is p = ρgh, where ρ is density, g is standard gravity 9.80665 m/s², and h is vertical head in metres. The result is in pascals. Divide by 1,000 for kilopascals, by 100,000 for bar, or multiply pascals by the standard conversion factor for pounds per square inch.
The pressure is gauge pressure relative to the free surface’s surrounding pressure. It does not add atmospheric pressure to produce absolute pressure. Keep the reference explicit when comparing readings; an instrument may display gauge or absolute pressure, and confusing those quantities creates a large offset.
Static column is not a flowing pipe calculation
The equation assumes a static fluid column. Once water is flowing, pressure at a point may also be affected by velocity, friction, fittings, pumps, valves, elevation changes, and water hammer. The calculator does not request pipe diameter, flow, roughness, or component losses, so it cannot predict a complete operating pressure in a distribution line.
USGS describes hydrostatic pressure and pressure head in relation to a water column. Use the result to understand the elevation component or to make a simple static comparison, not to size pipe, certify a pressure vessel, or diagnose a dynamic system. For equipment ratings and safe operating limits, follow the relevant manufacturer and engineering requirements.
Density and temperature matter
Density scales the result directly: if the fluid density is 2% higher while head stays fixed, calculated pressure is also 2% higher. Fresh water near common ambient conditions is close to 1,000 kg/m³, but salt content, dissolved material, and temperature can shift that value. Enter a documented density when precision matters.
Do not use the water default automatically for oil, brine, or another liquid. The tool allows density values through 20,000 kg/m³, but acceptance by the input does not establish that a particular fluid or system is safe. A physically appropriate fluid property and a correctly located reference point remain the user's responsibility.
Interpret static pressure at a stated reference point
Pressure head is useful because the same vertical head gives the same gauge pressure for a specified fluid density under the model’s gravity assumption. A point 10 m below an open water surface has about 98.07 kPa of static gauge pressure when density is 1,000 kg/m³. A higher measurement point has less head and therefore less hydrostatic pressure.
When comparing with a pump or gauge, state whether the surface is open to atmosphere, where the measurement point sits, and whether the system is still or flowing. If the reference surface is itself pressurized, that pressure must be considered separately; this calculator only supplies the elevation-generated component.
Worked examples
Both examples use gauge pressure from head and density, then convert pascals into common pressure units.
A 7.5-metre water head
Inputs: Vertical head = 7.5 m; density = 1,000 kg/m³.
Calculation: p = 1,000 × 9.80665 × 7.5 = 73,549.875 Pa = 73.549875 kPa ≈ 73.5499 kPa = 0.73549875 bar ≈ 0.73550 bar.
The static gauge pressure is about 73.55 kPa, or 0.73550 bar, before any flow or equipment effects.
A denser fluid at 12 metres of head
Inputs: Vertical head = 12 m; density = 998 kg/m³.
Calculation: p = 998 × 9.80665 × 12 = 117,444.4404 Pa = 117.4444404 kPa ≈ 117.4444 kPa = 1.174444404 bar ≈ 1.17444 bar.
The static gauge estimate is about 117.44 kPa. The density input is explicit; the number is not an absolute system pressure.