Available net positive suction head calculator
Estimate pump suction head above vapor pressure from absolute suction pressure and fluid conditions. Enter your values below to see the result and method.
inputs.
Related calculators
These tools cover nearby questions while keeping this page focused on its own calculation.
How to use this calculator
Estimate pump suction head above vapor pressure from absolute suction pressure and fluid conditions.
- Enter Absolute suction pressure (kPa), Vapor pressure (kPa), Fluid density (kg/m³), Suction velocity (m/s). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Define the component and operating point
Use this estimate to size or check one part of a system from explicit inputs. Estimate pump suction head above vapor pressure from absolute suction pressure and fluid conditions.
Inputs and units
Enter the values below for this model. Absolute static pressure at the pump suction, not gauge pressure; convert kPa to a pressure head using the entered fluid density. Absolute vapour pressure of the liquid at its operating temperature, in kPa. Density of the liquid at the pump suction or at the stated depth, in kg/m³. Mean liquid velocity at the pump suction section; its kinetic head is v²/(2g).
- Absolute suction pressure (kPa): Absolute static pressure at the pump suction, not gauge pressure; convert kPa to a pressure head using the entered fluid density.
- Vapor pressure (kPa): Absolute vapour pressure of the liquid at its operating temperature, in kPa.
- Fluid density (kg/m³): Density of the liquid at the pump suction or at the stated depth, in kg/m³.
- Suction velocity (m/s): Mean liquid velocity at the pump suction section; its kinetic head is v²/(2g).
Design equation and example
NPSHₐ = (pₛ − pᵥ)/(ρg) + v²/(2g)
At 150 kPa suction, 3 kPa vapor pressure, water density, and 1 m/s, NPSHₐ≈15.04 m.
Intermediate values are kept unrounded; the displayed result is rounded for readability.
Applying the result in a system
NPSH available is suction head above vapor-pressure head; compare it with the pump’s required NPSH at the actual flow and liquid temperature. Real installations can add losses, tolerances, boundary conditions, or code requirements beyond this model.
Assumptions and limitations
Simplified suction-plane estimate; elevation, losses, pressure datum, and pump manufacturer NPSH requirements must be checked.
Frequently asked questions
What pressure head is available above the liquid’s vapour pressure?
NPSHₐ = (pₛ − pᵥ)/(ρg) + v²/(2g) At 150 kPa suction, 3 kPa vapor pressure, water density, and 1 m/s, NPSHₐ≈15.04 m.
What can make a real installation differ from this available net positive suction head estimate?
Simplified suction-plane estimate; elevation, losses, pressure datum, and pump manufacturer NPSH requirements must be checked.
How do I use the Available net positive suction head calculator?
Enter Absolute suction pressure (kPa), Vapor pressure (kPa), Fluid density (kg/m³), Suction velocity (m/s). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Available net positive suction head?
NPSHₐ = (pₛ − pᵥ)/(ρg) + v²/(2g) At 150 kPa suction, 3 kPa vapor pressure, water density, and 1 m/s, NPSHₐ≈15.04 m. Intermediate values are kept unrounded; the displayed result is rounded for readability.
What does the Available net positive suction head calculator calculate?
Estimate pump suction head above vapor pressure from absolute suction pressure and fluid conditions.
Read the calculation methodology and privacy policy.