Building energy use intensity calculator

Normalize a building’s annual energy use by its gross floor area to calculate site energy use intensity (EUI).

4,000 tools
Building energy use intensity calculator — Annual site energy use (kWh/year), Gross floor area, Area unit and calculation method
Building energy use intensity calculator: inputs and calculation method.

How to use this calculator

Normalize a building’s annual energy use by its gross floor area to calculate site energy use intensity (EUI).

  1. Enter Annual site energy use (kWh/year), Gross floor area, Area unit. Match the units shown beside each field and review the result together with the assumptions below.
  2. Read the worked example below to check the expected input format and result.
  3. Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Energy calculation

How this calculation works

Energy use intensity compares a building’s annual energy consumption with its floor area. It is useful for tracking one property over time or preparing a basic size-normalized figure before a more complete benchmark that accounts for building type, weather, occupancy, and energy source.

Inputs and units

annualKwh — Annual site energy use (kWh/year)
Total annual site-delivered energy after converting included fuels to kWh on a consistent basis.
floorArea — Gross floor area
Gross floor area for the same building boundary covered by the energy total.
areaUnit — Area unit
Choose the unit used for the gross floor area entry.

Formula

Displayed formula

Site EUI = total annual site energy ÷ gross floor area. If area is entered in square feet, square metres = square feet ÷ 10.7639104167. The calculator reports kWh/m²-year and kWh/ft²-year.

Method

Add the building’s annual delivered energy in kWh on a consistent site-energy basis, then enter gross floor area in the selected unit. The output is annual kWh divided by area. Convert fuels to compatible energy units before combining them.

Worked example

A building using 180,000 kWh/year across 1,500 m² has site EUI = 180,000 ÷ 1,500 = 120 kWh/m²-year. The same area is about 16,145.9 ft², so the alternate figure is about 11.15 kWh/ft²-year.

Assumptions and limits

This simple EUI is not an ENERGY STAR score and does not normalize for weather, property type, occupancy, operating hours, or source-energy conversion. Use consistent floor-area boundaries and annual periods when comparing properties; a benchmark requires the relevant program’s full rules.

Frequently asked questions

What does a building’s EUI measure?

It is annual energy use divided by the building’s gross floor area, so the result expresses energy per unit of area per year.

Is this the same as an ENERGY STAR score?

No. This is a simple site-EUI calculation; ENERGY STAR benchmarking applies property-type and other program-specific methods.

Can I combine electricity and natural gas?

Yes, after converting each annual amount to a consistent energy unit and clearly choosing a site-energy basis.

How do I use the Building energy use intensity calculator?

Enter Annual site energy use (kWh/year), Gross floor area, Area unit. Match the units shown beside each field and review the result together with the assumptions below.

What is a worked example of Building energy use intensity?

A building using 180,000 kWh/year across 1,500 m² has site EUI = 180,000 ÷ 1,500 = 120 kWh/m²-year. The same area is about 16,145.9 ft², so the alternate figure is about 11.15 kWh/ft²-year.