How to use this calculator
Locate the theoretical zero-pressure depth in a dry cohesive cut and integrate only the compressive portion of its active pressure diagram.
- Enter Cut height (m), Unit weight (kN/m³), Cohesion intercept (kPa), Friction angle (degrees). Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Cohesive cut tension crack and active force explained
Use Cut height (m) with Unit weight (kN/m³) to reproduce the sample calculation, then review the stated limits before carrying the result into another scenario.
A numerical walkthrough
Cut height (m) = 4; Unit weight (kN/m³) = 18; Cohesion intercept (kPa) = 12; Friction angle (degrees) = 25.
- Positive active thrust: 13.284881 kN/m
- Theoretical tension-crack depth: 2.092914 m
- Ideal unsupported limiting height: 4.185828 m
For a 4 m cut with γ=18 kN/m³, c=12 kPa and φ=25°, the predicted crack truncates the upper portion of the active diagram.
The model behind the numbers
σh=Kaγz−2c√Ka; zc=2c/(γ√Ka); P+=Kaγ max(H−zc,0)²/2. Ideal Hcrit=2zc.
Soil is not assumed to sustain the negative tensile part of the Rankine diagram. The theoretical height is shown to illustrate the model, not as permission to leave an excavation unsupported.
What to enter
H— Cut height (m)- Height of an ideal vertical unsupported cut.
g— Unit weight (kN/m³)- Uniform total soil weight in the dry model.
c— Cohesion intercept (kPa)- Constant effective cohesion for the ideal c–φ soil.
phi— Friction angle (degrees)- Drained friction angle used for Rankine active pressure.
Interpreting the result
Dry homogeneous c–φ soil, no surcharge and no water-filled crack. Real fissures, softening and water can invalidate the apparent cohesive stand-up effect. Educational model; this is not a code-compliant design check.
Reading the outputs
Positive soil thrust is kN/m; crack depth and idealized limiting height are metres. A crack depth greater than H means no compressive thrust within this ideal diagram.
Frequently asked questions
Does zero computed thrust imply a safe cut?
No. The model omits progressive cracking, weathering, water and construction disturbance.
What if rain fills the crack?
Hydrostatic crack loading must be analyzed separately; this dry calculation is then incomplete.
Why display a crack deeper than the excavation?
It indicates the theoretical stress intercept lies below the current cut, rather than a measured crack depth.
How do I use the Cohesive cut tension crack and active force calculator?
Enter Cut height (m), Unit weight (kN/m³), Cohesion intercept (kPa), Friction angle (degrees). Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Cohesive cut tension crack and active force?
Cut height (m) = 4; Unit weight (kN/m³) = 18; Cohesion intercept (kPa) = 12; Friction angle (degrees) = 25. Positive active thrust: 13.284881 kN/m Theoretical tension-crack depth: 2.092914 m Ideal unsupported limiting height: 4.185828 m For a 4 m cut with γ=18 kN/m³, c=12 kPa and φ=25°, the predicted crack truncates the upper portion of the active diagram.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
Reference access note: The linked FHWA Volume II PDF was not retrievable during this review. The stated equation and numerical example were checked independently; verify against the manual before using for design.
Read our calculation methodology.