How to use this calculator
Integrate active and passive soil thrusts over a smooth vertical wall while adding hydrostatic pressure separately.
- Enter Retained height (m), Effective friction angle (degrees), Soil total unit weight (kN/m³), Water-table depth (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
- Read the worked example below to check the expected input format and result.
- Compare another scenario by changing one input at a time. Use Reset to return to the starting values.
Rankine active passive wall pressure with groundwater explained
Integrate Rankine active or passive effective soil pressure over wall height and add groundwater pressure separately.
A numerical walkthrough
Retained height (m) = 4; Effective friction angle (degrees) = 30; Soil total unit weight (kN/m³) = 20; Water-table depth (m) = 2; Uniform surcharge (kPa) = 10.
- Active thrust including water: 79.7422 kN/m
- Passive thrust including water: 560.7734 kN/m
- Active coefficient: 0.333333
- Hydrostatic thrust: 19.6133 kN/m
A 4 m wall retains 20 kN/m³ soil at φ=30°, with a water table 2 m deep and 10 kPa surcharge. The 2 m submerged portion produces 19.6133 kN/m water thrust.
The model behind the numbers
Ka=(1−sinφ)/(1+sinφ), Kp=1/Ka; P=K∫σ′v dz+∫u dz. Water pressure is not multiplied by K.
The soil component uses effective overburden and surcharge. Groundwater contributes both a reduction in effective stress and its own horizontal hydrostatic force.
What to enter
H— Retained height (m)- Wall height over which horizontal forces are integrated.
phi— Effective friction angle (degrees)- Drained soil friction angle for level cohesionless backfill.
g— Soil total unit weight (kN/m³)- Uniform total unit weight; hydrostatic pore pressure is separated below the water table.
zw— Water-table depth (m)- Depth below backfill surface; a depth at least H means no water pressure on the retained height.
q— Uniform surcharge (kPa)- Broad uniform surface surcharge acting over the active/passive soil zone.
Interpreting the result
Level cohesionless backfill, vertical frictionless wall, adequate movement to mobilize the selected limiting state. No seismic, compaction or drainage-reliability check. Educational model; this is not a code-compliant design check.
Reading the outputs
Active and passive resultants are kN per metre of wall; Ka is dimensionless and hydrostatic thrust is shown separately.
Frequently asked questions
Is passive resistance always available?
No. It requires adequate soil and movement; excavation, disturbance and design factors can reduce usable resistance.
Should water pressure use Ka?
No. Hydrostatic pressure acts independently of soil friction.
What about a wall that cannot move?
Use an at-rest stress model rather than assuming active pressure is mobilized.
How do I use the Rankine active passive wall pressure with groundwater calculator?
Enter Retained height (m), Effective friction angle (degrees), Soil total unit weight (kN/m³), Water-table depth (m), then complete the remaining labeled fields. Match the units shown beside each field and review the result together with the assumptions below.
What is a worked example of Rankine active passive wall pressure with groundwater?
Retained height (m) = 4; Effective friction angle (degrees) = 30; Soil total unit weight (kN/m³) = 20; Water-table depth (m) = 2; Uniform surcharge (kPa) = 10. Active thrust including water: 79.7422 kN/m Passive thrust including water: 560.7734 kN/m Active coefficient: 0.333333 Hydrostatic thrust: 19.6133 kN/m A 4 m wall retains 20 kN/m³ soil at φ=30°, with a water table 2 m deep and 10 kPa surcharge. The 2 m submerged portion produces 19.6133 kN/m water thrust.
Background or definition reference: FHWA Soils and Foundations Reference Manual, Volume II.
The linked FHWA Earth Retaining Structures manual is an official reference, but its large PDF could not be inspected here. This calculator is a Rankine idealization for level cohesionless backfill and a vertical frictionless wall; confirm project-specific assumptions and design factors.
Read our calculation methodology.